En5335Qi-T Pin Descriptions - Denon AVR-2310 Service Manual

Av surround receivers and amplifiers
Hide thumbs Also See for AVR-2310:
Table of Contents

Advertisement

EN5335QI-T Pin descriptions

PIN
NAME
1-7
NC
8-14
VOUT
15-16
NC
17-18
PGND
19-20
PGND
21-24
PVIN
25-26
NC
27
ROCP
28
AVIN
29
AGND
30-31
NC
32
VS2
33
VS1
34
VS0
35
POK
36
VSENSE
37
SS
38
EAIN
39
EAOUT
40
COMP
41
ENABLE
42-44
NC
NO CONNECT – Do not electrically connect these pins to each other or to
PCB. CAUTION!: May be internally connected.
Regulated converter output. Connect these pins to the load and place output
capacitor from these pins the PGND pins 17-18
NO CONNECT – Do not electrically connect these pins to each other or to
PCB.
CAUTION!: Internally connected to switching node.
Output power ground. Connect these pins to the ground electrode of the
output filter capacitors. Refer to layout guideline section.
Input power ground. Connect these pins to the ground electrode of the Input
filter capacitors. Refer to layout guideline section
Input power supply. Connect to input power supply. Decouple with input
capacitor to PGND (pins 19-20).
NO CONNECT – Do not electrically connect these pins to each other or to
PCB. CAUTION! May be internally connected.
Optional Over Current Protection adjust pin. Place ROCP resistor between
this pin and AGND (pin 40) to adjust the over current trip point.
Analog voltage input for the controller circuits. Connect this pin to the input
power supply.
Analog ground for the controller circuits.
NO CONNECT – Do not electrically connect these pins to each other or to
PCB. CAUTION! May be internally connected.
Voltage select line 2 input. See Table 1.
Voltage select line 1 input. See Table 1.
Voltage select line 0 input. See Table 1.
Power OK is an open drain transistor for power system state indication. POK
is a logic high when VOUT is with -10% to +20% of VOUT nominal.
Remote voltage sense input. Connect this pin to the load voltage at the point
to be regulated.
Soft-Start node. The soft-start capacitor is connected between this pin and
AGND. The value of this resistor determines the startup timing.
Optional Error Amplifier input. Allows for customization of the control loop.
Optional Error Amplifier output. Allows for customization of the control loop.
Optional Error Amplifier Buffer output. Allows for customization of the control
loop.
Input Enable. Applying a logic high, enables the output and initiates a soft-
start. Applying a logic low disables the output.
NO CONNECT – Do not electrically connect these pins to each other or to
PCB. CAUTION! May be internally connected.
AVR-2310CI/2310/890, AVC-2310
FUNCTION