Installing Lp Gas Tank - Uniflame GBC1405SP Owner's Manual

Outdoor lp gas barbecue grill
Table of Contents

Advertisement

Available languages

Available languages

Recipes
BlueRhino.com/recipes

Installing LP Gas Tank

To operate, you will need one precision-filled standard grill LP gas
tank with external valve threads.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this
grill.
Insert and Secure LP Gas Tank
Place precision-filled LP gas tank upright into the notches in the right cart frame so the tank
valve is facing the gas line connection.
Secure tank by sliding the tank retainer wire over shoulder of LP gas tank.
Connecting LP Gas Tank
1.
Before connecting, be sure there is no debris caught
in the head of the LP gas tank, head of the regulator
valve or in the head of the burner or burner ports.
2.
Connect regulator/hose assembly to tank by turning
knob clockwise until it stops.
Disconnecting LP Gas Tank
1.
Before disconnecting, make sure the LP gas tank valve
is "CLOSED."
2.
Disconnect regulator/hose assembly from LP gas tank
by turning knob counterclockwise until it is loose.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to
moving this grill.
3.
Place the protective cap cover on the LP tank and
store the tank outdoors in a well ventilated area out of
direct sunlight.
Getting More Propane
Need a tank of gas? One option is to try propane exchange. It's easy, fast,
safe, and available at tens of thousands of conveniently located retail
outlets nationwide, which are typically open nights and weekends. You
can purchase a fresh, precision-filled tank or exchange your empty for a
fresh, precision-filled tank. Another option is to have your tank refilled at a
refill station. Be sure to check the hours of operation for the refill station.
Need help? 1.800.762.1142
Do not return to place of purchase.
20 lb
9 Kg
12.2 in. / 31 cm
Replacement Parts
parts.BlueRhino.com /
1.800.762.1142
Operating Instructions
Checking for Leaks
Burner Connections
1.
Make sure the regulator valve and hose
connections are securely fastened to the burner
and the tank.
2.
Visually check the connection between the
burner/venturi tube and orifice.
3.
Make sure the burner/venturi tube fits over the
orifice.
W WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury or damage to
property.
4.
Please refer to diagram for proper installation
(Figure 1).
5.
If the burner/venturi tube does not rest flush
to the orifice, as shown, please contact
1.800.762.1142 for assistance.
Tank/Gas Line Connection
1.
Make 2-3 oz. of leak detection solution by mixing
one part liquid dishwashing soap with three parts
water.
2.
Make sure control knobs are in the " OFF"
position (Figure 2).
3.
Connect LP gas tank per "Installing LP Gas Tank"
section.
4.
Turn LP gas tank valve to "OPEN."
5.
Spoon several drops of solution, or use a squirt
bottle, at all "X" locations (Figures 1 and 3).
a. If any bubbles appear, turn LP gas tank valve to
"CLOSED," reconnect and re-test.
b. If you continue to see bubbles after several
attempts, turn LP gas tank valve to "CLOSED"
and disconnect LP gas tank, per "Disconnect
LP Gas Tank" section. Contact 1.800.762.1142
for assistance.
c. If no bubbles appear after one minute, turn
LP gas tank valve to "CLOSED," wipe away
solution and proceed.
Operating Main Burners
First Use
1.
Make sure all labels, packaging and protective
films have been removed from the grill.
2.
Remove manufacturing oils before cooking on
this grill for the first time by operating the grill
for at least 15 minutes on (HIGH) with the lid
closed. This will "heat clean" the internal parts
and dissipate odors.
Lighting
W CAUTION: Keep outdoor gas cooking appliance area clear and free
from combustible materials, gasoline and other flammable vapors and
liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
W CAUTION: Attempting to light the burner with the lid closed may cause
an explosion.
1.
Open lid.
2.
Check for obstructions of airflow to the burners. Spiders, insects and webs can clog the
burner/venturi tube. A clogged burner tube can lead to a fire.
3.
All control knobs must be in the " OFF" position (Figure 2).
4.
LP gas tank per "Installing LP Gas Tank" section.
5.
LP gas tank valve to "OPEN."
6.
Push and turn any control knob to (HIGH).
7.
Press the (igniter) button quickly 3 to 4 times to light burner.
8.
If ignition does not occur in 5 seconds, turn burner control knob " OFF," wait 5 minutes,
and repeat lighting procedure.
9.
If igniter does not light burner, use a lit match secured with the lighting rod (included with
grill) to light burners. Access the burners through the cooking grid and heat plates. Position
9
Figure 1: Main Burners
LP Gas Valve
with Orifice
Burner/
Venturi
Valve
Tube
Soft Pipe
Connection
Figure 2
OFF
ARRÊT
Figure 3
X
X
X
X
X
Figure 4
Match
Lighting
Rod

Hide quick links: