ASA Electronics AOM561 Troubleshooting Manual

Asa electronics lcd monitor troubleshooting guide

Advertisement

Monitor will not power up – no backlight on power button
• Confirm 12v+ to monitor.
• Confirm ground connection.
• Check vehicle's fuse and circuit for proper operation.

No image on screen

• Verify cable is connected to monitor.
• Verify camera is connected to cable.
• Connect known good camera and cable to monitor.
o If image appears connect cable to existing camera.

Input does not trigger properly (Standby or otherwise)

• See owner's manual for proper wiring.
• Confirm 12v + to trigger lead.
o Note: Trigger will remain active as long as there is 12VDC+ to that wire,
preventing control or access to other inputs/cameras.
B. Woods
Tech Services
05.04.07
AOM561 Troubleshooting Guide
If image remains replace original cable.
If image disappears replace original camera.