Conventional Detector Interface
GIF8-1
• For the connection of 8 detector
lines in addressable conventional
technology
• Individual detector addressing with
optional address module
• Individual setting of detector zone
function
• Lines monitored for wire breakage,
short circuit, and short to earth
Description
The Conventional Detector Interface GIF8-1 supports
eight detector zones in addressable conventional tech-
nology in Fire Detection Control Panels Series BC216.
Up to 64 detectors (addresses) per detector line can
be individually identifi ed with the aid of an address mo-
dule.
In the event of an alarm, the fi re detection control panel
indicates the number of the detector that is activated
fi rst and displays the optionally parameterised text in-
formation. Depending on the type of detector (manual
Building Safety. Building Security.
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED
call point, automatic fi re detector with or without alarm
verifi cation, fault message contacts as well as contacts
for technical messages), the function of the detector
zone can be set separately for each detector line.
The Conventional Detector Interface provides a proces-
sor of its own. At a possible central processing board
failure, the diversifi ed redundancy concept thus ensures
reliable alarm recognition. Each input of the Conventio-
nal Detector Interface is protected against overvoltage
and thus provides high system stability.
A
GIF8-1_DBL_LST_EN_0804.PDF • PAGE 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the GIF8-1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LST GIF8-1

  • Page 1 • Lines monitored for wire breakage, short circuit, and short to earth Description The Conventional Detector Interface GIF8-1 supports eight detector zones in addressable conventional tech- nology in Fire Detection Control Panels Series BC216. Up to 64 detectors (addresses) per detector line can be individually identifi...
  • Page 2 Building Safety. Building Security. © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27 OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED typ. 50mA (8 zones terminated, without detectors) typ. 20V typ.