GAI-Tronics 10959-207 Operation, Installation And Service Manual

Rack-mount audio messenger interfaces
Hide thumbs Also See for 10959-207:

Advertisement

Quick Links

Rack-Mount Audio Messenger Interfaces
Confidentiality Notice .....................................................................................................................1
Product Overview ............................................................................................................................1
Features .................................................................................................................................................... 1 
Options ..................................................................................................................................................... 2 
Configurations ......................................................................................................................................... 2 
Alarms ................................................................................................................................................................... 2
Inputs/Outputs ....................................................................................................................................................... 2
Timed Events ........................................................................................................................................................ 2
Optional Telephone Operation .............................................................................................................................. 3
®
Operation .......................................................................................................................................... 3
Optional ADVANCE Operation ........................................................................................................................... 4
Optional Zone Operation ...................................................................................................................................... 4
Optional AMI Redundancy ................................................................................................................................... 4
Installation ......................................................................................................................................5
Field Wiring ............................................................................................................................................. 6 
Digital Outputs ...................................................................................................................................................... 6
Digital Inputs ........................................................................................................................................................ 7
Audio .................................................................................................................................................................... 8
System ................................................................................................................................................................... 8
Ethernet ................................................................................................................................................................. 8
Power .................................................................................................................................................................... 9
Optional PBX Connection .................................................................................................................................... 9
®
........................................................................................................................................................... 9
Settings and Adjustments ..............................................................................................................10
Opening the Unit ................................................................................................................................... 10 
Level Adjustments ................................................................................................................................ 11 
Display Brightness .............................................................................................................................................. 11
Phone Line Levels .............................................................................................................................................. 11
Party Line Levels ................................................................................................................................................ 11
Page Line Levels ................................................................................................................................................. 11
Jumper Settings ..................................................................................................................................... 11 
600-Ohm Line Termination ................................................................................................................................ 11
AUDBUS1 Termination ..................................................................................................................................... 11
AUDBUS2 Termination ..................................................................................................................................... 11
Audio Contact Supervision ................................................................................................................................. 11
Date and Time Set Up ........................................................................................................................... 13 
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
V
ISIT WWW
G A I - T R O N I C S
A H U B B E L L C O M P A N Y
T
A B L E O F
610-777-1374  800-492-1212  Fax: 610-796-5954
.
-
.
GAI
TRONICS
COM FOR PRODUCT LITERATURE AND MANUALS
®
C O R P O R A T I O N
C
O N T E N T S
Pub. 42004-404F
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 10959-207 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GAI-Tronics 10959-207

  • Page 1: Table Of Contents

    AUDBUS2 Termination ............................. 11   Audio Contact Supervision ..........................11   Date and Time Set Up ........................... 13  GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA 610-777-1374  800-492-1212  Fax: 610-796-5954 ISIT WWW TRONICS COM FOR PRODUCT LITERATURE AND MANUALS...
  • Page 2 Table of Contents Pub. 42004-404F 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Date Set Up ................................. 13   Time Set Up ................................ 13   Operation ............................14   LCD Display at Initial Power Up......................14  LCD Display during Operation ......................15 ...
  • Page 3: Confidentiality Notice

    GAI-Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.
  • Page 4: Options

    Pub. 42004-404F 2 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Options  Telephone access  ® Integration to Page/Party systems  Up to 40 general inputs and 40 general outputs  Routability to eight controlled audio zones ...
  • Page 5: Optional Telephone Operation

    Pub. 42004-404F 3 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Optional Telephone Operation The Telephone Interface has multiple operational modes. The appropriate mode is configurable by the AMI Configuration Tool software application. The AMI can provide passcode-protected telephone access to the system. The AMI can be configured to allow telephone access only if the correct Remote Access Security Code is entered.
  • Page 6: Optional Advance Operation

    Pub. 42004-404F 4 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Optional ADVANCE Operation ® The Page/Party operation allows for the AMI to play messages/alarms and connect phone calls to an ADVANCE system. When the AMI is interfaced to an ADVANCE system, the operation of the telephone interface is as described above, and includes all page modes.
  • Page 7: Installation

    Um die Brandgefahr zu verringern, verwenden Sie bitte nur Fernmeldekabel der Stärke Nr. 26 AWG oder höher. Model 10959-207 and –208 Rack-Mount AMI units can be placed on a table or desk, or can be mounted in a standard EIA 19-inch electronic equipment rack. The 10959-207/8 AMI requires 1U (1.75 inches) in a standard 19-inch rack.
  • Page 8: Field Wiring

    Pub. 42004-404F 6 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Field Wiring Figure 3. Back of rack with connections labeled Digital Outputs The terminal block labeled provides eight digital common ground outputs. The DIGITAL OUTPUTS outputs are open collector active low. The controlled circuit must use the same voltage used to power the AMI.
  • Page 9: Digital Inputs

    Pub. 42004-404F 7 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Table 2. Digital Output Assignment Metalwork Internal Terminal Function or ACT Label Pin-Out Description TB1-1 Ground or dc common TB1-2 Output 1 TB1-3 Output 2 TB1-4 Output 3...
  • Page 10: Audio

    Pub. 42004-404F 8 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Audio The terminal block labeled provides connections for audio inputs and outputs, and for local AUDIO RS-485 data connections. Audio connections to a public address amplifier require shielded pair conductors.
  • Page 11: Power

    Metalwork Internal Terminal Label Pin-Out Function or ACT Description Party L1 P1-1 The 33-ohm line interface to GAI-Tronics party line. Internal 33-ohm termination. Party L2 P1-2 Page L1 P1-3 The 33-ohm line interface to GAI-Tronics page line. External 33-ohm termination required.
  • Page 12: Settings And Adjustments

    Pub. 42004-404F 10 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Settings and Adjustments Opening the Unit If installed in a card rack, remove the four 10-32  ¾-inch screws holding the unit in the rack and pull the unit out.
  • Page 13: Level Adjustments

    Pub. 42004-404F 11 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Level Adjustments Display Brightness R237 on the Main PCBA adjusts the brightness of the LCD display on the front of the assembly. Phone Line Levels On the optional Telephone Interface PCBA two potentiometers adjust phone audio levels. The Receiver Volume potentiometer, R36, adjusts the volume level from the telephone line.
  • Page 14 Pub. 42004-404F 12 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Table 8. Termination PCBA Jumper Functions Jumper Output Position Function TB3-5, 6 600-ohm resistor connected (ADVANCE position) Audio bus 1 Default: unterminated TB3-1, 2 600-ohm resistor connected (ADVANCE position)
  • Page 15: Date And Time Set Up

    Pub. 42004-404F 13 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Date and Time Set Up Date Set Up Push buttons on the front of the unit allows for date set up. Complete the following procedure to set the date.
  • Page 16: Operation

    Pub. 42004-404F 14 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Operation ® Once the CompactFlash is programmed and installed into the unit, the unit operates based on system inputs and outputs or by manual operation from the front of the rack-mount unit.
  • Page 17: Lcd Display During Operation

    Pub. 42004-404F 15 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES LCD Display during Operation The LCD uses various symbols to indicate AMI activity.  The VU meter indicates the volume of a page playing.  Mute indicates the page audio is muted.
  • Page 18: Push-Button Operation

    Pub. 42004-404F 16 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Push-Button Operation The front panel push buttons allow for various control features including, Play a Message, Stop a message, and Firmware Update. Stop Message This function halts the currently playing message. The button sequence is used: ...
  • Page 19: Ami Configuration Tool (Act)

    Pub. 42004-404F 17 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES AMI Configuration Tool (ACT) Overview The Audio Messenger Interface Configuration Tool (ACT) software is used to define and change configurations for the Audio Messenger Interface (AMI), and is included with all models of AMI. To ®...
  • Page 20: Outputs

    Pub. 42004-404F 18 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES Outputs Each output circuit must be enabled or disabled. If enabled, it must be programmed with several parameters such as:  Title, which contains a brief text description of the output and its use ...
  • Page 21: Compactflash

    Pub. 42004-404F 19 of 20 10959-207 -208 R ODEL OUNT UDIO ESSENGER NTERFACES CompactFlash ® ® The CompactFlash memory card stores the system configuration, speech messages, and alarm tones. Formatting ® All new CompactFlash memory cards must be formatted specifically for use with the AMI. Formatting is accomplished using the following DOS-format command from Windows command prompt: ®...
  • Page 22: Replacement Parts

    Digital outputs ......................... Open collector Maximum output sink current ..................100 mA per output Maximum output voltage ....................AMI input voltage Isolated output .............. Dry contact or GAI-Tronics proprietary supervision Digital inputs ....................Open collector or dry contact Enclosure Material ..........Steel body with aluminum cover; black, fine-textured paint finish Mounting ......................
  • Page 23 Warranty Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and if applicable, shall be fit for the purpose specified in the agreed-upon quotation or proposal document.

This manual is also suitable for:

10959-208

Table of Contents