Models 10959-207 and -208 Rack-Mount
Audio Messenger Interface
Confidentiality Notice .....................................................................................................................1
Product Overview ............................................................................................................................1
Features .................................................................................................................................................... 1
Options ..................................................................................................................................................... 2
Functions .................................................................................................................................................. 2
Alarms ................................................................................................................................................... 2
Inputs/Outputs ....................................................................................................................................... 2
Timed Events ........................................................................................................................................ 2
Optional Telephone Operation (Model 10959-208 only) ..................................................................... 3
®
Operation .......................................................................................................................... 3
Optional ADVANCE Operation ........................................................................................................... 3
Optional Zone Operation ...................................................................................................................... 4
Optional AMI Redundancy ................................................................................................................... 4
Installation ......................................................................................................................................4
Mounting .................................................................................................................................................. 5
Desktop installations ............................................................................................................................. 5
Rack Installations .................................................................................................................................. 5
Field Wiring ............................................................................................................................................. 6
Digital Outputs ...................................................................................................................................... 6
Digital Inputs ........................................................................................................................................ 7
Audio..................................................................................................................................................... 8
System ................................................................................................................................................... 8
Ethernet ................................................................................................................................................. 9
Power .................................................................................................................................................... 9
Optional PBX Connection (Model 10959-208 only) ............................................................................ 9
®
........................................................................................................................................... 9
Auxiliary Microphone ......................................................................................................................... 10
Settings and Adjustments ..............................................................................................................11
Opening the Unit ................................................................................................................................... 11
Level Adjustments ................................................................................................................................ 12
Display Brightness .............................................................................................................................. 12
Phone Line Levels ............................................................................................................................... 12
Party Line Levels ................................................................................................................................ 12
Page Line Levels ................................................................................................................................. 12
Jumper Settings ..................................................................................................................................... 12
600-Ohm Line Termination ................................................................................................................ 12
AUDBUS1 Termination ..................................................................................................................... 12
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374  800-492-1212  Fax: 610-796-5954
V
ISIT WWW
G A I - T R O N I C S
A H U B B E L L C O M P A N Y
T
A B L E O F
.GAI-TRONICS.
COM FOR PRODUCT LITERATURE AND MANUALS
®
C
O N T E N T S
Pub. 42004-404G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 10959-207 and is the answer not in the manual?

Questions and answers

Summary of Contents for GAI-Tronics 10959-207

  • Page 1: Table Of Contents

    Page Line Levels ..........................12 Jumper Settings ............................. 12 600-Ohm Line Termination ........................ 12 AUDBUS1 Termination ........................12 GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA 610-777-1374  800-492-1212  Fax: 610-796-5954 .GAI-TRONICS. ISIT WWW COM FOR PRODUCT LITERATURE AND MANUALS...
  • Page 2 Communications ........................... 20 I/O Control ............................20 Environmental ............................21 FCC Information ..........................21 Approvals ............................21 Replacement Parts.........................21 GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA 610-777-1374  800-492-1212  Fax: 610-796-5954 .GAI-TRONICS. ISIT WWW COM FOR PRODUCT LITERATURE AND MANUALS...
  • Page 3: Confidentiality Notice

    TRONICS retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-TRONICS product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.
  • Page 4: Options

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 2 of 21 Options  telephone access  desktop paging microphone  up to 40 general inputs and 40 general outputs  routability to eight controlled audio zones ...
  • Page 5: Optional Telephone Operation (Model 10959-208 Only)

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 3 of 21 Optional Telephone Operation (Model 10959-208 only) The Model 10959-208 AMI can provide passcode-protected telephone access to the system to allow telephone access only if the correct Remote Access Security Code is entered. The remote access code is used to prevent unwanted callers from directly accessing the system.
  • Page 6: Optional Zone Operation

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 4 of 21 Scheduled events and live pages can be played through the ADVANCE system to a specified zone group. Zone groups are configured using the ACT tool and the ADVANCE system configuration software.
  • Page 7: Mounting

    Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 5 of 21 Mounting The Model 10959-207 and -208 Rack-Mount AMI units can be placed on a table or desk, or can be mounted in a standard EIA 19-inch electronic equipment rack. Desktop installations 1.
  • Page 8: Field Wiring

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 6 of 21 Field Wiring Figure 3. Back of rack with connections labeled Digital Outputs Terminal block TB1, labeled DIGITAL OUTPUTS, is located on the rear of the AMI. It provides eight digital common ground outputs.
  • Page 9: Digital Inputs

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 7 of 21 Table 2. Digital Output Connections Metalwork Internal Function or ACT Label Terminal Pin-Out Description TB1-1 Ground or dc common TB1-2 Output 1 TB1-3 Output 2 TB1-4...
  • Page 10: Audio

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 8 of 21 Audio Terminal block TB3, labeled AUDIO, is located on the rear of the AMI. It provides connections for audio inputs, audio outputs, and local RS-485 data connections. Audio connections to a public address amplifier require shielded pair conductors.
  • Page 11: Ethernet

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 9 of 21 Ethernet The Ethernet connector is reserved for future implementation. Power Terminal block TB6, labeled CLASS 2 12 –24 VDC, is located on the rear of the AMI. It provides the required 12–24 V dc power connection to the AMI.
  • Page 12: Auxiliary Microphone

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 10 of 21 Auxiliary Microphone Jack J1, located on the front panel of the AMI, provides connectivity for an auxiliary microphone. The pinout for the microphone jack is as follows: Table 8.
  • Page 13: Settings And Adjustments

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 11 of 21 Settings and Adjustments Opening the Unit Rack Installations: 1. Label and disconnect all wiring to the AMI. 2. Remove the four 10-32  ¾-inch screws holding the unit in the rack.
  • Page 14: Level Adjustments

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 12 of 21 Level Adjustments Display Brightness Adjust potentiometer R237, on the main PCBA, to change the brightness of the LCD display on the front of the assembly. Phone Line Levels Two potentiometers on the optional telephone interface PCBA adjust the telephone audio levels: ...
  • Page 15 Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 13 of 21 Figure 5. Termination PCBA Table 9. Termination PCBA Jumper Functions Jumper Output Position Function 600-ohm resistor connected (ADVANCE position) TB3-5, 6 Audio bus 1 Default: unterminated...
  • Page 16: Date And Time Set Up

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 14 of 21 Date and Time Set Up Date Set Up Use the push buttons located on the front of the AMI to set the date (see Figure 4 for the push-button locations).
  • Page 17: Configurable Parameters

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 15 of 21 Configurable Parameters Fragments ® All tones and voice messages are digitally recorded and stored on the CompactFlash card as audio fragments stored in MP3 files. Messages Each message is a collection of fragments.
  • Page 18: Optional Telephone Interface

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 16 of 21 Optional Telephone Interface Configure the following parameters if using the telephone interface:  number of rings before answer  paging mode (live or recorded)  page delay, if recorded ...
  • Page 19: Operation

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 17 of 21 Operation ® The AMI operates based on system inputs and outputs or by manual operation after the CompactFlash has been programmed and installed in the unit.
  • Page 20: Lcd Display During Operation

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 18 of 21 LCD Display during Operation The LCD uses various symbols to indicate AMI activity:  The VU meter indicates the volume of a page playing.  Mute indicates the page audio is muted.
  • Page 21: Push-Button Menu Operation

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 19 of 21 Push-Button Menu Operation Front panel push buttons provide menu access for various control features including; play a message, stop a message, and firmware update. Stop Message This menu item halts the currently playing message.
  • Page 22: Specifications

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 20 of 21 Specifications Power Supply Voltage ................. 12 to 24 V dc (UL listed) Class 2 power source (plug-in 12 V dc power supply included with AMI) Current ........................... 1 A (minimum) Power consumed .........................
  • Page 23: Environmental

    Pub. 42004-404G Models 10959-207 and -208 Rack-Mount Audio Messenger Interface Page 21 of 21 Environmental Temperature range ................... +32 ºF to +122 ºF (0 ºC to +50 ºC) FCC Information Complies with CFR47, Part 15 ......................Class A Approvals Safety of Information Technology Equipment..UL 60950, CAN/CSA-C22.2 No. 60950-00, IEC 60950 Replacement Parts Table 10.
  • Page 24 Warranty Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and if applicable, shall be fit for the purpose specified in the agreed-upon quotation or proposal document.

This manual is also suitable for:

10959-208

Table of Contents