DOS ASPI Driver Error Messages

Message
LSI Logic ASPI Manager has
NOT been loaded.
Controller setup FAILED
error code=[0xab]
No non-disk devices were
located
'ERROR: VDS support is
*INACTIVE* for
MegaRAID Express logical
drives
104
MegaRAID Express 500 Hardware Guide
Corrective Action
The ASPI manager is not loaded. One of the failure
codes listed below is displayed next.
Correct the condition that caused the failure. The failure
codes are:
0x40
No MegaRAID adapters found
0x80
Timed out waiting for interrupt to be posted
0x81
Timed out waiting for MegaRAID Express
500 Response command.
0x82
Invalid command completion count.
0x83
Invalid completion status received.
0x84
Invalid command ID received.
0x85
No MegaRAID Express adapters found or no
PCI BIOS support.
0x90
Unknown Setup completion error
The driver did not find any non-hard drive devices
during scanning. A SCSI device that is not a hard disk
drive, such as a tape drive or CD-ROM drive, must be
attached to this SCSI channel. The SCSI ID must be
unique for each adapter and cannot be SCSI ID 0. The
supported SCSI IDs are 1, 2, 3, 4, 5, and 6.
The /h option is appended to driver in
CONFIG.SYS or this driver is used with a BIOS that is
earlier than v1.10, or no logical drives are configured.