Installation (continued)
3
Installing the range hood
As per Fig . 7, cut the required hole in the cabinet .
- Lift the range hood (A) up under the cabinet to determine
its final position. Fix the unit onto the cabinet with 6pcs of
M5 x 12 mm tapping screws.
- If the bottom of the cabinet is recessed, add a wood filler
on each side . The wood strips must be as thick as the
recess . Use appropriately sized wood screws to attach the
wood filler to its location.
*** Make sure the opening hole size is 15 in. (380 mm) L x 10 1/4
in. (260 mm) on the bottom of the cabinet to the fit the range hood.
4
Attaching the duct
- Attach your ducting (6) (not supplied) to the range hood (A)
and connect the duct to your exterior exhaust system.
5
Final step
- Reconnect the power supply cable and wires to the
electrical supply . Turn the power on and ensure that the
lights and fan are operating correctly .
A
Bottom View
Wood filler strips
Cabinet bottom
Wall
A
12
6