Daily Maintenance (whenever using the heater) - Continued

Check Firepot for Clinkers

If the flames seem to be coming
only from the sides, or are
orange/black, turn the heater off
and check for clinkers.
The most likely causes are:
Restrictor needs adjustment
(see "Restrictor Adjustment" in
the installation section of this
manual)
Poor pellet quality
The door or glass has an air leak
The exhaust system requires
cleaning

Cleaning the Firepot

WARNING:
Make sure the
heater has fully
cooled
(approximately 25
minutes) before
opening the door
and conducting
service.
To clean the firepot,
open the door (see page
26) and knock away any
debris on the firepot with
a screwdriver. If severely
clogged, remove the
firepot to gain better
access.