(1) this device may not cause harmful interference. and (2) this device must accept any interference received, including interference that may cause undesired operation. LOGIC CONTROLS, INC. 355 Denton Ave New Hyde Park, NY 11040 TEL: (516) 248-0400 FAX: (516) 248-0443 Email: lci@logiccontrols.com...
CARTON CONTENTS ... 2 HARDWARE CONNECTIONS ... 3 FUNCTIONAL TEST ... 4 UTILITY DISK CONTENTS ... 6 INSTALLING THE LK7000.EXE UTILITY PROGRAM ... 7 STARTING THE LK7000.EXE PROGRAM ... 7 PROGRAMMING THE LK7000 KEYBOARD ... 8 ADVANCED PROGRAMMING ... 10 SPECIAL FEATURES OF THE LK7000 ...
HARDWARE CONNECTIONS The LK7000 can be connected to an IBM101 PC, XT, AT or clone computer, PS/2 computer, or computer terminal. The following diagram shows how the keyboard connects to the computer and standard keyboard or other keyboard peripheral (magnetic stripe reader, scanner, etc.).
FUNCTIONAL TEST For testing purposes, your LK7000 keyboard was pre-programmed with a template called LK7000.TPL. The following simple steps will verify that the keyboard is in good working condition: 1. Follow the Hardware Connections procedure described earlier in this manual to connect the LK7000 to your computer.
The first step in using the LK7000D.EXE utility program is to copy the program to your hard drive. 1. Insert the LK7000 utility software into drive A or B of the computer. 2. Type MD LK7000 at the “C>“ prompt to make a directory named LK7000.
Note that the PC must be booted up in DOS before starting the program. It will not run properly under Windows DOS prompt. To start the program, type LK7000D at the LK7000 DOS prompt and press ENTER. When the program is up, it will automaticallly display the graphic...
2. Enter your programming text via the 101 keyboard. Continue programming until all the keys are programmed. It is not necessary to program all the keys for the LK7000 to function properly. The maximum number of alphanumeric characters that can be programmed for any one key is 256.
Page 12
5. Type S to save the programmed data into the LK7000 directory. You can select up to an 8 character name. It will be saved with a .TPL extension. 6. Press ESC to terminate the Data Transfer Menu. 7. Press F10 followed by Y to exit the utility program.
To enter hex scan-codes directly, press ESC followed by the 2-digit hex number. For example, to program the CTRL key press ESC followed by 1D. The LK7000 program will add the leading zero...
SPECIAL FEATURES OF THE LK7000 Besides being able to program all the keys of an IBM101 keyboard, the LK7000 has also incorporated three state-of-the-art features which will add flexibility and functionality to the keyboard. INTER-STRING DELAY This feature allows for a time delay(s) to be installed after a character(s) has been inserted into a cell.
MULTI-LEVEL DEFINITION This feature can increase the apparent number of programmable keys by allowing you to program different levels into any cell. For every different level you program you must select another key to be a “SHIFT LEVEL” key. Programming is accomplished in the normal manner. After programming the base level a separator bar must be entered to separate the base level from the second level.
Page 16
8. Change the programming mode of this cell to the scan-code mode (F8). Depress and hold the ALT key while depressing the letter A twice. Two triangles inside brackets will appear on the programming line. 9. To use this feature in your application is extremely simple. When medium coffee is desired just press the F5 key (the first level of information stored in cell F5 will be sent to the computer).
SPECIAL CONFIGURATIONS The keyboard can be set up with many different programming options. To activate the configuration menu screen press F3. By depressing the high- lighted letter in each option, the program will enable or disable that option. The default settings are shown in the graphic below. Send Break-codes for scan-codes Enable beep while a key pressed No beep if a key is undefined...
Page 18
DESCRIPTION OF SPECIAL CONFIGURATION MENU F3 Send Break-code for scan-codes - Enables or disables the transmission of break codes for each scan code programmed into the keyboard. Enable beep while a key pressed - Enables or disables the entire keyboard from beeping when any key is depressed.
Parity - This option selects ODD, EVEN or NO parity. Length of data - This option selects either 7 or 8 data bits. DATA TRANSFER MENU COMPUTER'S S ave L oad COMPUTER'S HARD DISK W rite MEMORY R ead LK7000 KEYBOARD...
Page 20
7 seconds. Enables the computer to read (R) a template stored in the LK7000. That template can then be saved (S) to the hard disk for future use.
LK7000 PROGRAMMABLE KEYBOARD SPECIFICATIONS MECHANICAL Weight Basic Unit with MSR with Scanner Dimension (in inches) Width 15.7 Depth Front Height 0.5 Rear Height 1.8 w/legs ext. 2.2 Keys Full travel mechanical Life cycle >10 million tactile cycles 2 tracks standard...
TO ACTIVATE THE SCANNER The top right key on the LK7000 has been hardwired to the scanner, and serves as the scanner’s trigger. This key is dedicated to activating the scanner.