Replacing The Fuses - Circuit-test DMR-6700 User Manual

Multimeter true rms
Table of Contents

Advertisement

WARNING: To avoid electric shock, do not operate the meter until the bat-
tery cover is in place and fastened securely.
NOTE: If your meter does not work properly, check the fuses and batteries to
make sure that they are still good and that they are properly inserted.

Replacing the Fuses

WARNING: To avoid electric shock, disconnect the test leads from any
source of voltage before removing the fuse cover.
1. Disconnect the test leads from the meter.
2. Remove the protective rubber holster.
3. Remove the battery cover (two "B" screws) and the battery.
4. Remove the six "A" screws securing the rear cover.
5. Gently remove the old fuse and install the new fuse into the holder.
6. Always use a fuse of the proper size and value (0.5A/1000V fast blow
for the 400mA range, 10A/1000V fast blow for the 10A range.
7. Replace and secure the rear cover, battery and battery cover.
WARNING: To avoid electric shock, do not operate your meter until the fuse
door is in place and fastened securely.
- 20 -