Summary of Contents for Circuit-test DMR-3600

  • Page 1: Digital Multimeter

    OWNER’S MANUAL Digital Multimeter DMR-3600 CIRCUIT-TEST ELECTRONICS LTD A Division of R.P. Electronic Components Ltd. Burnaby, BC, Canada V5C 5Y1 www.circuittest.com...
  • Page 2: Safety Precautions

    INTRODUCTION Your Circuit-Test DMR-3600 Digital Multimeter incorporates the latest tech- nology providing you with a feature packed instrument. With it you can measure a wide range of voltages, current, inductance, capacitance and resistance in the lab, shop, car and home. This meter has been designed for the Electrician, Technologist, Hobbyist and Educational Institutions.
  • Page 3: Special Function

    High voltage AC and DC circuits are dangerous. Use caution when working above 60VDC or 30VAC rms as these voltages pose a shock hazard. Always consider circuits to be energized. Never assume any equipment is de- energized. Lack of caution or poor safety practices can be very dangerous and/or lethal.
  • Page 4: Dc Voltage Measurement

    Capacitance: 4n-40n-400n-4µ-400µF ± (5% + 10), ±(8% + 10) (above 100µF) (Test voltage: 3V / Test frequency: 4n-40nF 1KHz; 400n-4µF 70Hz; 400µF 7Hz) 4K-40K-400K-4000KHz ± (0.5% + 1) Frequency: (Autoranging) (Sensitivity: 0.2Vrms minimum) 4m-40m-400m-40H ± (5% + 10) Inductance: 4H ± (5% + 20) (Test frequency: 4m-40mH 1KHz;...
  • Page 5: Ac Voltage Measurement

    Apply the test leads to the circuit to be measured. Ensure that the black lead is connected to the negative side of the circuit and the red lead to the positive. Read the displayed voltage. If the minus (-) sign appears the voltage is negative at the point being measured.
  • Page 6: Ac Current Measurement

    4 AC CURRENT MEASUREMENT WARNING: Remove all power from circuit being tested when check- ing current. When using the 10A range do not connect to the circuit for more than 60 seconds and wait 10 minutes between 10A meas- urements. Plug the red test lead into the mA jack and the black test lead into the COM jack.
  • Page 7: Continuity Test

    3. When using the 4000 M Ω range a fixed 20 count must be subtracted in order to obtain a true measurement. For example when measuring a resistance of 1200M Ω , the display will read 1220M Ω . 6 CONTINUITY TEST WARNING: Remove all power from circuit being tested when check- ing continuity.
  • Page 8: Frequency Measurement

    9 FREQUENCY MEASUREMENT WARNING: Maximum input is 500 V. Plug the red test lead into the VΩ jack and the black test lead into the COM jack. Set the range switch to the KHz setting. Connect the probes to the point of measurement. Read the displayed frequency.
  • Page 9: Battery Replacement

    13 BATTERY REPLACEMENT WARNING: Disconnect both test leads from any equipment before removing back cover. Do not use meter with case opened. 13-1 The “ ” will appear on the display when the battery requires replacing. 13-2 Disconnect both test leads and turn off the power. 13-3 Remove the screws in the rear cover of the case and remove the cover.
  • Page 10 Fuses: AGX 0.5A/250V & TUE 10A/600V LIMITED WARRANTY Circuit-Test Electronics warrants to the original purchaser that this product be free of defect in material or workmanship for a period of 2 years from the date of purchase. If this product requires warranty service, return the unit...