Advertisement

Quick Links

USER'S MANUAL
DIGITAL MULTIMETER
DMR-4350
CIRCUIT-TEST ELECTRONICS
www.circuittest.com

Advertisement

Table of Contents
loading

Summary of Contents for Circuit-test DMR-4350

  • Page 1 USER'S MANUAL DIGITAL MULTIMETER DMR-4350 CIRCUIT-TEST ELECTRONICS www.circuittest.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY Safety Information ........2 Safety Symbols .
  • Page 3: Safety Information

    SAFETY INFORMATION This meter is CUL and UL approved and conforms to IEC 61010-1 for Cat- egory III - 600V and Category II - 1000V. This meter is designed to be safe under the following conditions: indoor use, altitude up to 2000m, temperature 5°C to 40°C, maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C and rated pollution degree 2.
  • Page 4: Safety Symbols

    SAFETY SYMBOLS Safety symbols and special annunciators on the meter and in this manual indicate cautions and warnings of important operational procedures that must be followed to ensure personal and product safety. This symbol indicates a General Warning. When adjacent to a termi- nal or operating device indicates that the operator must refer to an explanation in the Operating Instructions.
  • Page 5: Introduction

    INTRODUCTION DMR-4350 is a True RMS Auto Ranging meter featuring an analog bargraph for easy viewing of measurement changes. This meter can measure/test the following: – Voltage – Current – Resistance – Continuity – Diode – Temperature LCD DISPLAY SYMBOL DEFINITIONS...
  • Page 6: Front Panel Description

    CIRCUIT-TEST DMR-4350 POWER RANGE HOLD AUTO POWER Ω C° F° µA µA TRUE RMS TEMP V/Ω / for 15 sec MAX every 30 min FUSED 320mA 1000 VDC 750 VAC FUSED 20A MAX CAT III 600V CAT II 1000V µA/mA...
  • Page 7: Specifications

    SPECIFICATIONS GENERAL Display: digit 3200 count LCD Maximum Display: 3200 Ranging: Auto/Manual Auto Shut-off: Meter will shut-off after 10 minutes from last use Polarity: Automatic, minus (-) sign indicates negative polar- ity, no sign for positive polarity Measuring rate: 3 times/sec Input impedance: 10M (DCV / ACV) Diode Test:...
  • Page 8: Ranges And Accuracy

    RANGES AND ACCURACY FUNCTION RANGE RESOLUTION ACCURACY DC VOLTAGE 326mV 0.1mV ±(0.5% reading + 5 digits) (DC V) 3.26V 32.6V 10mV 326V 100mV 1000V AC VOLTAGE 3.26V ±(0.8% reading + 8 digits) (AC V) 32.6V 10mV 326V 100mV 750V DC CURRENT 326µA 100nA ±(1.2% reading + 5 digits)
  • Page 9: Operating Instructions

    OPERATING INSTRUCTIONS This meter comes with an exclusive patented technology featuring bright LEDs indicating the correct input jack to plug-in the positive (red) test lead for the selected function. The LED turns off after the test lead is completely plugged in the correct jack. If the test lead is plugged in the wrong jack, the LED will start flashing and the buzzer will start beeping.
  • Page 10: Dc Voltage Measurement

    V/ / / ➔ Plug the red test lead in V/ / / jack and black test lead in jack. CIRCUIT-TEST DMR-4350 + DC – POWER ➔ Apply the test leads to the circuit RANGE HOLD to be measured. Ensure that the Ω...
  • Page 11: Dc Current Measurement

    ➔ Plug the red test lead in V/ / / jack and black test lead in jack. ➔ Apply the test leads to the circuit to CIRCUIT-TEST DMR-4350 POWER be measured. RANGE HOLD ➔ Read the displayed TRMS voltage. Ω...
  • Page 12: B) 326Ma Or More Dc Current

    ➔ ʻAʼ appears on the display and the LED above 20A jack turns on. ➔ Plug the red test lead in 20A jack and black test lead in the jack. CIRCUIT-TEST DMR-4350 POWER + DC – ➔ Remove power from the circuit that RANGE HOLD is to be measured.
  • Page 13: B) 326Ma Or More Ac Current

    µA/mA jack turns on. ➔ Plug the red test lead in µA/mA jack and black test lead in the jack. CIRCUIT-TEST DMR-4350 POWER ➔ Remove power from the circuit that RANGE HOLD is to be measured. Open up the Ω...
  • Page 14: Resistance Measurement

    ➔ Plug the red test lead in V/ / / jack and black test lead in jack. CIRCUIT-TEST DMR-4350 POWER RESISTOR ➔ Apply the test leads to the resistor RANGE being measured. If the resistor is HOLD Ω...
  • Page 15: Continuity Test

    ➔ next to V/ / / jack turns on. ➔ Plug the red test lead into the jack and the black test V/ / / CIRCUIT-TEST DMR-4350 WIRE POWER lead into the jack. RANGE HOLD ➔ Apply the test leads to the circuit.
  • Page 16: Temperature Measurement

    ➔ Apply the test leads across the diode terminals and note the meter reading. ➔ Reverse the diode and note this reading. Based on the readings the result can be evaluated as follows: CIRCUIT-TEST DMR-4350 POWER RANGE – If one reading is around 0.5 HOLD and the other reading is ʻOLʼ, Ω...
  • Page 17: Range Function

    ➔ Set the function switch to OHMS, VOLTS, DC AMPS or AC AMPS. ➔ Plug the test leads into their appropriate jacks. CIRCUIT-TEST DMR-4350 POWER ➔ Press the Range button once to deactivate AUTO RANGE HOLD mode. Each additional push causes the range to Ω...
  • Page 18: Battery Replacement

    11. BATTERY REPLACEMENT WARNING: DISCONNECT BOTH TEST LEADS FROM ANY SOURCE OF VOLTAGE BE- FORE REMOVING THE BACK COVER. DO NOT OPERATE THE METER UNTIL THE BACK COVER IS IN PLACE AND FASTENED SECURELY. will appear in the display when the battery drops below the operating voltage and requires replacing.
  • Page 19 b) 16 Amp Fast acting 6.3x32mm Ceramic Fuse (by a professional person only) ➔ Turn off the meter and disconnect both test leads. ➔ Remove the three screws at the back of the case (one at the top and two at the bottom).
  • Page 20: Maintenance

    Batteries: 2 x AAA LIMITED WARRANTY Circuit-Test Electronics warrants to the original purchaser that this product be free of defect in material or workmanship for a period of 2 years from the date of purchase. Visit our website (www.circuittest.com) for information on warranty service.