JOB NAME ______________________________________________________________________
LOCATION ______________________________________________________________________
ARCH./ENGR.____________________________________________________________________
WHOLESALER __________________________________________________________________
MECH. CONTRACTOR ___________________________________________________________
MODEL NO. _____________________________________________________________________
TYPE GAS ______________________________________________________________________
Btu/hr INPUT_____________________________________________________________________
Btu/hr OUTPUT___________________________________________________________________
NOTES
Standard Features
• 84% AFUE
• Two Stage Firing
• Sealed Combustion Chamber
• Stainless Steel Burners
• Low NOx Operation Exceeds the most
Stringent Air Quality Requirements
• ASME Copper Finned Tube Heat Exchanger
• 160 PSI Working Pressure
• Gasketless Heat Exchanger Design
• Automatic Reset High Limit
• Loch-Heat Ceramic Tile Combustion Chamber
• Hot Surface Ignition
• ASME Pressure Relief Valve
• 24 Volt Control System
• Pump Relay
• 10 Year Limited Warranty
on Heat Exchanger
(See warranty for details)
EFFICIENCY+
GAS BOILERS
®
Optional Equipment
Place an X in the box by all options that apply
Adjustable High Limit w/ Manual Reset
Alarm Bell
Cupro-Nickel Heat Exchanger
Flow Switch
Indoor/Outdoor Reset
Manual Reset Low Water Cut-Off w/test
MP
Stack Frame
Pump Delay w/ Freeze Protection
Firing Control Systems
M9 Hot Surface Ignition with Electronic Supervision
M7 California Code
EFFICIENCY+
BOILER
Submittal Sheet
EBN-Sub-05
2
Sequencer
(Standard)
®

Advertisement

loading

Summary of Contents for Lochinvar EBN-SUB-05

  • Page 1 Cupro-Nickel Heat Exchanger Flow Switch Indoor/Outdoor Reset Manual Reset Low Water Cut-Off w/test Sequencer Stack Frame Pump Delay w/ Freeze Protection Firing Control Systems M9 Hot Surface Ignition with Electronic Supervision (Standard) M7 California Code EFFICIENCY+ ® BOILER Submittal Sheet EBN-Sub-05...
  • Page 2: Venting Options

    Net ratings based on piping and pick-up allowance of 1.15 Conventional Efficiency + DirectAire Direct Vent Vertical Direct Vent Horizontal Outdoor Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000 Dimensions & Spec i fi ca tions 19-3/4” 16” 7-1/4” 23-3/4”...

This manual is also suitable for:

Efficiency+ ebn150Efficiency+ ebn200Efficiency+ ebn250Efficiency+ ebn300