10. MASTER ON/OFF
Set up master single send out ON/OFF
11. COOL MODE
1. STUDIO :
SETUPDIM 000%-080%,When the temperature is low 50℃,the fan will stop;but if
the temperature is over 50℃,the fan will circumvolve in slow speed; when the
temperature is over 70℃,DIM will drop to 60%.
2. REGULATED:
SETUPDIM 000%-100%,when the temperature is low 45℃,the fan will stop; when the
temperature is over 45℃ and low 55℃, the fan will circumvolve in slow speed; when
the temperature is over 55℃, the fan will circumvolve in fast speed; when the
temperature is over 60℃,DIM will drop 2% with temperature raising 2℃.
3. POWER :
SETUPDIM 000%-100%,the fan will circumove in fast speed;when the temperature is over
70℃,DIM will drop to 60%.