Set The Printer Parity; Restore Default Baud Rate - Brecknell CP103 User Instructions

Thermal mini printer
Table of Contents

Advertisement

4.2.4 Set the Printer Parity

Change the parity of the printer to match the host device.
1.
2.
Where n is the number associated with the desired parity
NOTE: Only changed if the Data Bit has been changed to 9.

4.2.5 Restore Default Baud Rate

Set factory default baud rate.
1.
2.
3.
4.
14
Go to the Testing tab.
Under the CMD Testing window (the top window) enter the following command
string:
+UART CRC:n
Go to the Testing tab.
Under the CMD Testing window (the top window) enter the following command
string:
1f 40
Click on the box to the left of HEX.
Click the [SEND] button. The typed in command string will be displayed in the
bottom window if the command was sent.
n
Parity
0
none (default)
1
even
2
odd
CP103 Thermal Printer User Instructions