Samsung CO88R Service Manual page 10

Table of Contents

Advertisement

4-7 Replacement of Fuse
1. Plug off the power cord.
2. Remove fuse cover and the fuse.
After replacement of fuse the fuse cover must
be reset.
4-8 Replacement of Lamp
1. Remove the wiring.
2. Remove the lamp attachment screw(1 piece)
and the lamp.
4-9 Replacement of Magnetron, Thermometal switch
1. Remove the wiring
2. Remove the support-MGT.(Screw 1 piece).
3. Remove the back-panel. (Screw seven piece)
4. Remove the BKT-HVT.(Screw: upper resp.
lower each two)
5. Remove the magnetron attachment
screws(four pieces) and then the magnetron.
6. Thermo switch is removed together with.
Care the high tension voltage when
removing wiring.
Samsung Electronics
Fuse cover
Support MGT
THERMOMETAL
attachment
Magnetron
screws(four pieces)
Disassembly and Reassembly
FUSE
LAMP
LAMP attachment screw
Back Panel
BKT HVT
MAGNETRON
4-3

Advertisement

Table of Contents
loading