Making Electrical Connections; Fitting/Setting Programmable Room Thermostat - Baxi 5117391 Installation & User's Instructions

Single channel wireless programmable room thermostat for use with all potterton combination boilers

Advertisement

MAKING THE ELECTRICAL CONNECTIONS -
If there is a 3-way Block with 2 black, 1 blue and 1 brown wires connected near the
Receiver then proceed as follows:
Remove and discard the wiring harness on the receiver.
The Receiver wiring is integral to the boiler and the 3-way Block is only a temporary
connection for when there is no integral control fitted.
Remove and discard the 3-way Block.
Connect:
the black wires to terminals 3 and 4,
the blue wire to terminal 2,
the brown wire to terminal 1 of the Receiver,
terminal 5 is not used.
Refit the Receiver Cover Panel, Facia and Outer Case.
If there is no 3-way Block (a) and no 3-way Connector (b) then proceed as
follows:
Cut off the Receiver 3-way Plug and strip the 3 wires for connection into the
6-way terminal block - see Fig. 1.
Remove the link wire between terminals 1 & 2.
Wire the blue wire into the neutral terminal.
Wire the brown wire into the terminal 1.
Wire the red wire into terminal 2.
Refit the Receiver Cover Panel, Facia and Outer Case.
FITTING THE PROGRAMMABLE ROOM THERMOSTAT
1. Ensure that there is power to the boiler.
2. Remove the rear panel of the transmitter, now correctly fit the batteries (2 x1.5V
LR6/AA) into the transmitter. The transmitter will start sending signals and within 10 - 20
seconds the receiver will pick up a signal, this can be confirmed by switching on the
transmitter to create a demand and observing the LED - see Operating Mode.
3. Secure the rear panel of the transmitter to a suitable wall in the living room or hall.
Refit the transmitter in place on the rear panel.
OPERATING RANGE: Within a building - up to 20 metres. Avoid positioning large
metallic objects, including mirrors, in the line - of - sight between the transmitter and
receiver.
NOTE: These components are 'RF Linked' and should be fitted as a pair, if they are
not, then recommissioning will be required.
RECOMMISSIONING
Press and hold the black button on the receiver, the LED light will flash immediately.
When it flashes again 2 or 3 seconds later release the button. The receiver LED light will
remain constantly ON, to indicate that it is now waiting for a corresponding signal from
the Programmable Room Thermostat Transmitter. The receiver will remain in this mode
for 3 minutes only.
The transmitter will start sending signals and within 10 - 20 seconds the receiver will pick
up a signal, this will be confirmed by the receiver's LED light going off. The transmitter
and receiver are now 'linked' so that the receiver will switch ON and OFF according to
the settings on the Programmable Room Thermostat Transmitter.
Slot for Flat Bladed
Screwdriver
(twist slightly to release)
Programmable Room
Rear Panel
Thermostat Transmitter
Batteries
b
br
1
2
3
4
5
3-way
Block
Receiver
Black Button
LED Light
OPERATING MODE
If the LED is Off then the Room Stat is Off.
If the LED is On then the Room Stat is On.
If the LED is Flashing once a second then the batteries
in the Room Stat are running out.
If the LED is Flashing 2 or 3 times a second then the
batteries in the Room Stat have run out.
There are 3 possible wiring arrangements (a) and (b) are the most common
If there is a 3-way Connector with a red wire looped between 2 pins near the Receiver
then proceed as follows:
Remove the Link Connector from the socket on the boiler harness and discard.
Connect the plug on the receiver harness into the socket.
Refit the Receiver Cover Panel, Facia and Outer Case.
Red Wire
Link
Connector
br - Brown
b - Blue
Socket
bl - Black
bl
PCB
a
Link
Wire
N
1
2
3
4
SETTING THE PROGRAMMABLE ROOM THERMOSTAT
To Set The Time: Slide the cover (A) off the unit. Rotate the timer clock clockwise
until the time is correct.
To Set The Central Heating ON/OFF Times: Move the tappets outwards for ON
times and inwards for OFF times.
To Set The Room Temperature: Rotate the room temperature dial until the desired
room temperature is selected.
To Set The Operating Mode: Slide the three position selector switch to the desired
position
On
= Continuously on
Timed = Central Heating ON/OFF times
controlled by the tappets
Off
= Continuously off
NOTE: Boiler is IPX0 when the receiver is fitted.
A
OPERATING RANGE: Within a building - up to 20 metres. Avoid positioning large metallic
objects, including mirrors, in the line - of - sight between the transmitter and receiver.
Receiver
Receiver
Harness
Socket
PCB
Receiver
Optional Live
Feed For An
External Pump
b
r
br
5
N
1
2
Rotate to
adjust time
Off
Off
Timed
Timed
Constant
Room Temperature Dial
12
9
3
6
5°C
30°C
10
15
25
20
b
Fig. 1
Optional Live
Feed For An
External Pump
c
3
4
5
Time Pointer
12
9
3
6
Tappet
On
Off Position
On Position
Quick Reference Guide