Active Care Medical Prowler 3410 Owner's Manual page 23

Hide thumbs Also See for Prowler 3410:
Table of Contents

Advertisement

Questions? Call 866.621.4933 or visit www.activecaremed.com.
The diagnostic flash codes for your scooter are designed to help you perform basic
troubleshooting quickly and easily. A diagnostic flash code flashes from the
diagnostic light in the event one of the conditions listed below develops.
Table 2: Scooter Controller Internal Diagnostics
Flash
Possible Cause
code
1
The battery needs charging
2
Battery voltage is too low
3
Battery voltage too high
4
Current limit time out
5
Park brake fault
6
Speed control out of neutral
7
Speed control fault
8
Motor fault
9
Internal (controller) fault
Prowler Owner's Manual
Solution
The battery voltage has
dropped below 23.3 volts in
neutral. Recharge batteries.
The battery has dropped
past 16.5 volts and is not
sufficient to allow safe
driving. Check the battery
condition and the
connections.
The battery has exceeded 32
volts. Check the battery
condition and the
connections.
The motor current has
reached too high a value.
Check the condition of the
motor and loom. Contact
your Service Agent.
Check park brake conditions.
Return speed pod to neutral
and rest system. Readjust
the speed lever to neutral if
necessary. Contact your
Service Agent.
Check speed pod wiring for
open or short circuits. Check
speed pot set-up. Contact
your Service Agent.
Contact your Service Agent.
Contact your Service Agent.