Contractor's electric 4 gallon hand carry air compressor
Hide thumbs Also See for D55150:
Table of Contents

Advertisement

Available languages

Available languages

pressure switch c ontacts and stop theaircompressor.
SAFETY RELIEF VALVE
This valve (B) is designed to prevent system failures by relieving
pressure from the system when the compressed
air reaches
a
predetermined
level. The valve is preset by the manufacturer and
must not be modified in any way.
AIR TANK DRAIN VALVE
The drain valve is used to remove moisture from the air tank after the
air compressor is shut off.
MOTOR THERMAL OVERLOAD
The electric
motor
has a manual
thermal
overload protector (C). If the
any reason, the thermal overload wilt cut
power, thus preventing
the motor from being
damaged. Turn the pressure switch to the OFF
position
and wait until the motor cools before
pressing the thermal overload button.
AIR INTAKE FILTER
This filter (D) is designed to clean air entering the pump. To ensure
the pump continually receives a clean, cool, and dry air supply this
filter must always be clean and the filter intake must be free from
obstructions.
TANK PRESSURE GAGE
The tank pressure gage indicates air pressure in the air tank.
REGULATED PRESSURE GAGE
The regulated pressure gage indicates the air pressure available at the
outlet side of the regulator. This pressure is controlled by the regulator and
is always less than or equal to the air tank pressure.
PRESSURE REGULATOR
The regulator knob controls the air pressure coming from the air tank.
OIL DIPSTICK
The dipstick (H) will indicate the amount of oil in the pump. Oil level should
be checked on a daily basis to ensure that it does not exceed the maximum
notch or fall below the minimum notch on the dipstick.
Common
Procedures
CHECKING COMPRESSOR
PUMP OIL LEVEL
WARNING:
Aftercooler,
pump
head,
and
surrounding
parts are very hot. Do not touch. (see
Hot Surfaces on page 4).
1. Ensure that the unit is off.
2. Locate unit on a flat horizontal surface.
3. Remove dipstick (H) from oil fill port.
4. Look for visual signs of contaminants
(water, dirt,
|
etc.) in oil on dipstick.
!
5. Wipe oil off of the dipstick.
6. Reinsert the dipstick fully into the oil fill port for a few
seconds to allow oil to collect on dipstick,
j
7. Remove the oil dipstick to read oil level. Oil should
not exceed top raised line (MAX) on dipstick. If oil is
below lower mark (MIN), add DEWALT synthetic oil MAX
and follow steps 5 through 7.
MIN
CHECKING SAFETY RELIEF VALVE OPERATION
WARNING: Aftercooler, pump head, and surrounding parts are
very hot. Do not touch (see Hot Surfaces on page 4).
1. Ensure that the unit is off.
2. Ensure that the tank is empty by looking at tank pressure gage.
Drain the tanks if necessary.
3. Grasp the wire ring on the safety valve.
4. Pull and release the ring a few times to ensure that the plunger
moves in and out. Replace the safety valve if plunger does not

Hide quick links: