DeWalt D55150 Instruction Manual page 6

Contractor's electric 4 gallon hand carry air compressor
Hide thumbs Also See for D55150:
Table of Contents

Advertisement

Available languages

Available languages

RISK OF EXPLOSION OR FIRE
It is normal for electrical contacts within the motor
and pressure switch to spark. Always operate the
compressor
in a welt-ventilated
area free
of
combustible materials, gasoline or solvent vapors. If
electrical sparks from compressor come into contact
with flammable vapors, they may ignite, causing fire
or explosion.
When spraying flammable
materials,
locate com-
pressor at least 20 feet upwind from spray area. An additional length
of hose may be required.
Store flammable
materials
in a secure location
away from the
compressor.
Restricting any of the compressor ventilation openings will cause
serious overheating
and could cause fire. Never place objects
against or on top of compressor. Operate the compressor in an open
area at least 3 feet away from any wall or obstruction
that would
restrict the flow of fresh air to the ventilation openings.
RISK OF ELECTRICAL
SHOCK
Your air compressor is powered by electricity. If it is
not used properly it could cause electric shock. Never
operate the compressor outdoors when it is raining or
in wet conditions.
Never operate compressor with guards or protective
covers that are damaged or removed. Repairs by anyone other than
qualified
personnel
can result
in serous
injury
or death
by
electrocution. Any electrical wiring or repairs required on this product
should be performed
by authorized
service center personnel
in
accordance with national and local electrical codes.
GROUNDING
INSTRUCTIONS
In the event of a malfunction or breakdown, grounding
provides a
path of least resistance
for electric current to reduce the risk of
electric shock. This tool is equipped with an electric cord having an 2
equipment-grounding
conductor and grounding plug. The plug must
be plugged into a matching outlet that is properly installed and
grounded in accordance with all local codes and ordinances. Do not
modify plug provided: if it wilt not fit the outlet, have the proper outlet
installed by a qualified electrician.
Improper connection of the equipment-grounding
conductor
can
result in a risk of electric shock. The conductor with insulation having
an outer surface that is green with or without yellow stripes is the
equipment-grounding
conductor.
If repair or replacement
of the
electric cord or plug is necessary
do not connect the equipment-
grounding conductor to a live terminal.
If the grounding Instructions are not completely understood or if in
doubt as to whether
the tool is properly grounded,
check with a
qualified electrician or service personnel.
Use only 3-wire extension cords that have 3-prong grounding plugs
and 3-pole receptacles to avoid overheating.
REPAIR OR REPLACE
DAMAGED
OR WORN CORDS IMME-
DIATELY.
THE USE OF A GFCI OUTLET IS RECOMMENDED AND MAY BE
REQUIRED IN CERTAIN AREAS.
Grounded tools intended for use on a supply circuit having a nominal
rating tess than 150 volts: This tool is intended for use on a circuit
that has an outlet that looks like the one illustrated in Figure A. The
tool has a grounding plug that looks like the plug illustrated in Figure
A. A temporary adapter, which looks like the adapter illustrated in
Figures B and C, may be used to connect this plug to a 2-pole
receptacle as shown in Figure B if a properly grounded outlet is not
available.
The temporary
adapter should
be used only until a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D55151D55155D55152D55153

Table of Contents