PUBLIC DDRESS POWER MPLIFIER
3. F N VENTS
These vents provide hot air flow out of the unit. It is important to keep them free of obstructions, to prevent the
unit from overheating. It is also important to operate the unit in a dust-free environment.
4. C POWER INPUT
Connect the supplied standard C input cable here.
5. FUSE HOLDER
This holder contains the
same type and rating.
If the fuse continues to blow, refer servicing to a qualified service technician.
6. HIGH-P SS FILTER SWITCH
This switch activates the high-pass filter circuitry, which decreases frequencies lower than 400Hz by –3dB.
The high-pass filter is designed to protect speakers from damage caused by excessive low frequency
transients.
7. UDIO INPUTS
These balanced XLR jacks are for the input of audio signal.
8. GROUND LIFT SWITCH
This switch provides for connection or disconnection of the amplifier's ground to
prevent noise from ground loops. Under most circumstances, this switch should be set to FR ME position.
9. DC INPUT TERMIN LS
These terminals are provided for the connection of backup battery. Connect a 24VDC(100 ) battery source
to these terminals. Make certain the red terminal is connected to the battery's positive (+) side, and the black
terminal to the battery's negative (-) side.
6
P -9312/9324/9336/9348
C overload protection fuse. If the fuse has blown out, replace it with a fuse of the
C "earth" ground, to