SYSTEM REPORTING CODES

✦ Refer to the System Reporting Codes table to
view/edit the reporting codes for the keypad
FIRE and EMERGENCY buttons and for each of
the three Control Panel conditions. The factory
settings are listed, along with a blank area to
write in the new installation values.
STEPS #261-266
Any value from 0-99 can be programmed for
each event using these steps (enter "0" to stop
an event from reporting).

FORCE ARMING REPORTING CODE

✦ The factory set reporting code for force arming is
"65" (Code 574 with Ademco).
STEP #258 Any value from 0-99 can be programmed for this
event using this step (0 = no report).
✎ NOTE: For force arming reporting, force arming
reports must be enabled. See Page 41.

DURESS REPORTING CODE

✦ The factory set reporting code for Duress is "66"
(Code 121 with Ademco).
STEP #259 Any value from 0-99 can be programmed for this
event using this step (0 = no report).
✎ NOTE: For duress code reporting a keypad duress
code must be programmed. See Page 34.
STEP #
PROGRAMMING FUNCTION
258
FORCE ARMING REPORT CODE
259
DURESS REPORT CODE
261
SYSTEM FIRE REPORT CODE
262
SYSTEM EMERGENCY REPORT CODE
263
SYSTEM TEST/CANCEL REPORT CODE
264
SYSTEM LOW BATTERY RESTORAL REPORT CODE
265
SYSTEM LOW BATTERY CODE
USER CODE
MASTER USER CODE1
RESTRICTED USER CODE #1
RESTRICTED USER CODE #2
RESTRICTED USER CODE #3
RESTRICTED USER CODE #4
RESTRICTED USER CODE #5
PAGE ALERT USER CODE
REMOTE/HARDWIRE ARM (SENSOR FCN. 9) & QUICK ARM
REMOTE/HARDWIRE DISARM (SENSOR FCN. 9)
SYSTEM REPORTING CODES
POSSIBLE
4 BY 2 VALUES
0 - 99
0 - 99
0 - 99
0 - 99
0 - 99
0 - 99
0 - 99
System Reporting Codes Table
OPENING & CLOSING REPORTING CODES TABLE
4 x 2 CLOSING
(ARMING) CODE
74
75
76
77
78
79
(DIALS PAGE NUMBER ONLY, NO CODES REPORTED)
81
Opening & Closing Reporting Codes Table
PROGRAMMING
STEPS #261 - 266
ENTERS STEP NUMBER
0 - 99 FOR SYSTEM
REPORTING CODE
STORES VALUE - 1 BING
PROGRAMMING STEP #258
ENTERS STEP NUMBER
0 - 99 FOR FORCE ARMING
REPORTING CODE
STORES VALUE - 1 BING
PROGRAMMING STEP #259
ENTERS STEP NUMBER
0 - 99 FOR DURESS CODE
STORES VALUE - 1 BING
FACTORY
ADEMCO VALUE
4 BY 2 VALUES
65
66
68
69
70
71
73
4 x 2 OPENING
ADEMCO CLOSING
(DISARMING) CODE
(ARMING) CODE
82
R401 C000
83
R401 C001
84
R401 C002
85
R401 C003
86
R401 C004
87
R401 C005
R407 C007
89
INSTALLATION
4 BY 2 VALUE
574
121
110
120
406
R302
E302
ADEMCO OPENING
(DISARMING) CODE
E401 C000
E401 C001
E401 C002
E401 C003
E401 C004
E401 C005
E407 C007