Hotpoint EG 900 X S Operating Instructions Manual page 6

Dual fuel cooker
Table of Contents

Advertisement

GB
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated on the data
plate. When connecting the cable directly to the mains, install an omnipolar
circuit-breaker with a minimum contact opening of 3 mm between the appliance
and the mains. The omnipolar circuit breaker should be sized according to
the load and should comply with current regulations (the earth wire should
not be interrupted by the circuit breaker).
The supply cable should be positioned so that it does not reach a temperature
of more than 50°C with respect to the room temperature, anywhere along
its length.
Before making the connection, check that:
• The electrical safety of this appliance can only be guaranteed if the cooker
is correctly and efficiently earthed, in compliance with regulations on
electrical safety. Always ensure that the earthing is efficient; if you have any
doubts call in a qualified technician to check the system. The manufacturer
declines all responsibility for damage resulting from a system which has
not been earthed.
• Before plugging the appliance into the mains, check that the specifications
indicated on the date plate (on the appliance and/or packaging) correspond
to those of the electrical mains system of your home.
• Check that the electrical capacity of the system and sockets will support
the maximum power of the appliance, as indicated on the data plate. If
you have any doubts, call in a qualified technician.
• If the socket and appliance plug are not compatible, have the socket
replaced with a suitable model by a qualified technician. The latter, in
particular, will also have to ensure that the cross section of the socket
cables are suitable for the power absorbed by the appliance. The use
of adapters, multiple sockets and/or extensions, is not recommended.
If their use cannot be avoided, remember to use only single or multiple
adapters and extensions which comply with current safety regulations. In
these cases, never exceed the maximum current capacity indicated on
the single adapter or extension and the maximum power indicated on the
multiple adapter.
! Once the appliance has been installed, the power supply cable and the
electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by authorised technicians
only (see Assistance).
! The manufacturer declines any liability should these safety measures
not be observed.
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
6
TABLE OF CHARACTERISTICS
Oven dimensions
HxLxP
Volume
Voltage and
frequency
N
L
Energy
Label e
Ecodesign
32,9 x 59,5 x 39,4 cm
lt. 78
230V-240V~ 50Hz (see data plate)
Power supply Max 2850-3100 W
EU Directive no 65/2014
supplementing Directive 2010/30/EU.
EU Regulation no 66/2014
implementing Directive 2009/125/EC.
Standard EN 60350-1,
Standard EN 30-2-1,
Standard EN 50564
Energy consumption for Natural
convection – heating mode:
Convection
mode
Declared energy consumption for
Forced convection Class – heating
mode:
Fan
assisted.
This appliance conforms to the
following European Economic
Community directives:
- 2006/95/EC dated 12/12/06 (Low
Voltage) and subsequent amendments.
- 2004/108/EC dated 03/05/89
(Electromagnetic Compatibility) and
subsequent amendments.
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EC dated 30/11/09 (Gas)
and subsequent amendments.
- 2012/19/EU and subsequent
amendments.
- 1275/2008 standby/off mode.

Advertisement

Table of Contents
loading