Problem
General
9.1
The compressor does not work.
9.2
The fridge operates frequently
or operates for a long time.
9.3
The compressor frequently
cycles on and off.
9.4
A beeping noise from inside the
fridge.
Cause
9.1.1
The refrigerator is in deep
freeze cooling
9.1.2
The refrigerator is not
powered on.
9.2.1
The room temperature or
ambient temperature is high.
9.2.2
The ice maker is in operation.
9.2.3
The doors or drawers are
frequently opened and
closed.
9.2.4
The control settings in
the freezer and fresh food
compartments are set to cold
level.
9.2.5
Door and/or drawer gasket
seals may be dirty, frayed or
cracked.
9.2.6
The condenser is dirty.
9.3.1
The compartment
temperature sensors keep
the fridge at the set points
causing the compressor to
cycle.
9.4.1
One door or drawer of the
fridge is open for over 60
seconds.
18
Solution
9.1.1.1
This is normal for a refrigerator that goes into
deep freeze automatically. The period of deep
freeze cooling lasts about 30 minutes.
9.1.2.1
Make sure the plug is inserted all the way into
the power outlet.
9.1.2.2
Has the circuit breaker tripped? Check and
change to a new 13 A fuse and/or reset the
circuit breaker.
9.1.2.3
Check the electrical supply to the room. Call the
local electricity company.
9.2.1.1
It is normal for the fridge to operate
continuously.
9.2.2.1
This is normal – the ice maker adds extra work
load in the refrigerator.
9.2.3.1
Try to reduce frequency of door or drawer
openings.
9.2.4.1
Raise up the compartment temperatures slightly
and allow 24 hours to reach new balance.
9.2.5.1
Clean off the gaskets and/or heat slightly with
hair dryer so gasket takes contour of metal
frame.
9.2.6.1
Clean the condenser.
9.3.1.1
This is normal. The fridge compressor will
provide the required cooling level.
9.4.1.1
This is normal and will repeat every 1 minute
until the door or drawer is closed.

Advertisement