Error Code Number Not Previously Described; Error During Function Change - Mira Vier User Manual

Wireless controller
Hide thumbs Also See for Vier:
Table of Contents

Advertisement

Error Code Number Not Previously Described

Error During Function Change

Control Sensor or PCB Relay
1. Turn Digital Mixer off for 15 seconds. Turn back on and
allow 15 seconds to reset.
2. If shower operation does not return to normal, replace
Thermistor. (To be performed by competent
tradesperson only!)
3. If shower operation does not return to normal, replace PCB.
(To be performed by competent tradesperson only!)
4. If problem still occurs, make a note of the error code and
contact our Customer Services Team.
Digital Mixer Temperature Motor
1. Turn Digital Mixer off for 15 seconds. Turn back on and
allow 15 seconds to reset.
2. If shower operation does not return to normal, check and,
if necessary, replace Mixer Valve. (To be performed by
competent tradesperson only!)
3. If problem still occurs, make a note of the error code and
contact our Customer Services Team.
Digital Mixer PCB Error.
1. Turn Digital Mixer off for 15 seconds. Turn back on and
allow 15 seconds to reset.
2. If problem still occurs, make a note of the error code and
contact our Customer Services Team.
Replace batteries.
Control out of range.
Displayed if there is a signal loss between the Wireless Control
Unit and the Digital Mixer whilst a function setting is being
altered. Press " " to clear the display and retry the function
change.