Comfort Glow CGP20T Owner's Operation And Installation Manual page 10

Blue flame vent-free propane/lp gas heater
Table of Contents

Advertisement

INSTALLING TO
WALL
Continued
10
If you install the heater in a home garage
• heater pilot and burner must be at least 18 inches above floor
• locate heater where moving vehicle will not hit it
For convenience and efficiency, install heater
• where there is easy access for operation, inspection, and service
• in coldest part of room
An optional fan kit is available from your dealer. See Accessories, page 30. If plan-
ning to use fan, locate heater near an electrical outlet.
Minimum
From
Sides Of
Heater
Left
Side
Figure 4 - Mounting Clearances As Viewed From Front of Heater
THERMOSTAT SENSING BULB
The thermostat sensing bulb has been placed inside the heater for protection during
shipping.
Locating Thermostat Sensing Bulb
1. Remove front panel of heater (see Figure 7, page 11).
2. Locate thermostat sensing bulb just under burner assembly.
IMPORTANT:
Attach thermostat sensing bulb to back of heater for proper operation.
Attaching Thermostat Sensing Bulb
1. Remove thermostat sensing bulb from holders inside heater. Route through slot
opening in bottom of heater.
2. Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in
hardware package.
3. Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is
located on lower left edge on back of heater. Make sure the thermostat sensing
bulb is pointing up.
Figure 5 - Attaching Thermostat Sensing Bulb
CAUTION
WARNING ICON
G 001
CEILING
6"
FLOOR
36"
Minimum
Right
Side
3"
Minimum To Top Surface
Of Carpeting, Tile Or Other
Combustible Material
Thermostat
Sensing Bulb
Clamp
103875