EverFocus EDSR100 Instruction Manual page 16

Digital single channel recorder
Hide thumbs Also See for EDSR100:
Table of Contents

Advertisement

Alarm Input
13
Alarm Input Terminal Block
ALM-IN :
Normal Open or Normal Close type alarm sensor input.
The Alarm Input can be selected as Normal Open or Normal Close input in the setup
menu. When an alarm occurs, alarm recording will automatically start.
ALM-RST : Normal Open or Normal Close type alarm reset input to reset the alarm.
REC :
External Recording request signal. The machine will start recording when a High Level
is applied on this input terminal. If the machine is not in the timer, recording mode,
the machine will stop recording when the REC signal drops from High to Low level.
Alarm Output
14
Alarm Output Terminal Block
ALM-NC :
Normal Close Alarm output. In normal condition, this terminal is
shorted to the terminal of ALM-COM. In alarm status, it is open
between ALM-NC and ALM-COM terminals.
ALM-NO : Normal Open Alarm output. In normal condition, this terminal is
open from the terminal of ALM-COM. In alarm status, those two
terminals are shorted.
ALM-COM : Alarm Common Contact.
SW OUT :
Step signal to synchronize the machine and multiplexer.
DISKFULL : Disk-Full alarm signal.
LAN
LAN Connector : Connect to the RJ-45 LAN connector.
15
RS232
RS232 connector : Connect D-Sub 9 pins connector to RS232 ports for remote control
16
Back Panel Connections
8

Advertisement

Table of Contents
loading

Table of Contents