ROBOTIC INTERFACE CONNECTION

Robotic interface can be made at the Remote
Receptacle (See Operation Section B-2). The machine
is shipped with the remote receptacle circuit internally
connected to receptacle J5 of the Control board for
standard Amptrol operation. In order to enable the
remote receptacle for robotic interface its connection
plug must be moved from J5 to J5A on the Control
board. (Refer to the machine Wiring Diagram.)
The robotic interface functions with the Precision TIG
set to either TIG or STICK mode, but must be in
REMOTE switch position for the Preset Control inter-
face to function. When in the REMOTE position with
robotic interface neither the MAXIMUM OUTPUT nor
the MINIMUM OUTPUT panel controls limit the inter-
face control setting over the rated output range of the
machine.
The diagram in Figure A.4 below shows the remote
receptacle plug connections and signals for robotic
interface:
ARC START
INPUT FROM ROBOT
(18Vac,10ma switch)
INSTALLATION
REMOTE RECEPTACLE
(Front View)
For 18-12P Plug
(LECO S12020-27)
C
B
D
*
E
A
F
*
Precision TIG Control Common.
PRECISION TIG 275
FIGURE A.4
PRESET CONTROL
INPUT FROM ROBOT
+
(0 -10Vdc = Rated Output Range)
Note: The Interface connection
+V
= 70Vdc max.
CC
cable may pick up noise
interference. Additional
bypass/filtering circuits may be
R = V
/ 5ma
CC
needed for the external circuits.
ARC ESTABLISHED
5ma
OUTPUT TO ROBOT
(High = Not Welding)
(Low = Welding)
Robotic
Common
A-8