To unmount indoor unit
Press the 2
marks on the lower part of the indoor
unit and unlatch the tabs. Then lift the indoor unit and
unmount. (Fig. 29)
3-9. Drain Hose
a) The drain hose should be slanted downward to the
outdoors. (Fig. 30)
b) Never form a trap in the course of the hose.
c)
If the drain hose will run in the room, insulate the
hose with insulation* so that chilled condensation
will not damage furniture or floors. (Fig. 31)
* Foamed polyethylene or its equivalent is recom-
mended.
Do not supply power to the
WARNING
unit or operate it until all tub-
ing and wiring to the outside
unit are completed.
Risk of Electric Shock
Push
Fig. 29
Indoor
unit
Fig. 30
Insulation material
(locally purchased)
must be used.
Fig. 31
17
Slant
Drain
hose
Condensation