Lincoln Electric IM869-D Operator's Manual page 28

Dc arc welding power source for use with machines having code numbers: 11198, 11322, 11407, 11409,11509
Table of Contents

Advertisement

E-5
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
No auxiliary power
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
POSSIBLE
CAUSE
FUNCTION PROBLEMS
1. Circuit Breakers open.
2. Faulty connections to auxiliary
receptacles.
3. GFCI Receptacle (if installed) may
have tripped.
CAUTION
SAE-400
RECOMMENDED
COURSE OF ACTION
1. Check and reset breakers. If
breakers keep tripping check con-
nections to auxiliary receptacles.
Also make sure load does nor
exceed receptacleʼs current rating.
2. Check connections.
3. Follow "GFCI Receptacle Testing
and Resetting Procedure" in the
MAINTENANCE section of this
manual.