Kenwood NXR-800 Service Manual page 78

Uhf digital base-repeater
Hide thumbs Also See for NXR-800:
Table of Contents

Advertisement

NXR-800
Item
Condition
2) SSG output: OFF
3) Analog Narrow
SSG setting
DEV: ±1.5kHz
4) SSG output: OFF
29. RSSI
Connect the SSG to the RX
ANT.
SSG setting
Frequency: Desired frequency
MOD: 1kHz
DEV: ±1.5kHz
Narrow
1) SSG output: –53dBm (501µV)
2) High Level
SSG output
: 12dB SINAD level +7dB
3) Low Level
SSG output
: 12dB SINAD level –2dB
30. Maximum
1) Analog Wide
Deviation
Connect the deviation meter
(Analog)
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 15kHz
De-emp: OFF
Detector: +peak, –peak
AG setting
: 1kHz/45mVrms
(Sine wave, Terminal load)
2) Analog Narrow
Connect the deviation meter
to the TX ANT end via the
ATT.
AG setting
: 1kHz/55mVrms
(Sine wave, Terminal load)
31. Standard
1) Analog Wide
Modulation
Connect the deviation meter
Check
to the TX ANT end via the
ATT.
Deviation meter setting
HPF: OFF
LPF: 15kHz
De-emp: OFF
Detector: (p-p)/2
AG setting
: 1kHz/±3kHz DEV
(Sine wave, Terminal load)
2) Analog Narrow
Connect the deviation meter
to the TX ANT end via the
ATT.
AG setting
: 1kHz/±1.5kHz DEV
(Sine wave, Terminal load)
78
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
Rear
RX ANT
Audio
TEST/
analyzer
SPKR
jack SPO
(pin 12)
4Ω load
SSG
Rear
RX ANT
AF V.M
TEST/
SPKR
jack
RSSI
(pin 8)
Deviation
Rear
TX ANT
meter
Front
MIC
AG
DVM
Deviation
Rear
TX ANT
meter
Front
MIC
AG
DVM
Adjustment
Parts
Method
Check
The squelch shall be closed.
PC
Adjust it to the level
ADJ
to open the squelch.
Check
The squelch shall be closed.
PC
3.5V
±0.1V
ADJ
Import the value to a
PC.
PC
±4.1kHz
±0.2kHz
ADJ
±1.7kHz
±0.1kHz
Check
4.5mV±1.5mV
5.5mV±1.5mV
Specifi cations / Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents