Kenwood NXR-800 Service Manual page 10

Uhf digital base-repeater
Hide thumbs Also See for NXR-800:
Table of Contents

Advertisement

NXR-800
2-4. Transmitter DDS circuit
The transmitter DDS circuit produces the transmitter
main PLL reference frequency signal 4.5MHz.
This circuit consists of IC307, IC202, CF201, Q210, Q211,
Q212 and Q213.
The 19.2MHz signal from the transmitter modulation
19.2MHz PLL circuit is amplifi ed by IC307 and supplied to
the IC202 reference signal pin.
IC202 produces the transmitter main PLL 4.5MHz refer-
5V #2
TX Mod
19.2MHz
19.2MHz
PLL circuit
IC307
2-5. Transmitter main PLL circuit
The transmitter main PLL circuit consists of the VCO
(Q102 and Q103), PLL IC (IC101), IC102, Q104 and Q106
and produces the transmitter frequency signal.
The VCO Q102 produces transmitter frequencies from
450.000MHz to 464.995MHz.
The VCO Q103 produces transmitter frequencies from
465.000MHz to 480.000MHz.
The signal produced by the VCO (Q102 or Q103) is fed to
the buffer amplifi er and is amplifi ed by Q106. The higher
harmonic wave is attenuated by LPF and returns to the PLL
IC (IC101).
IC101 divides the VCO oscillating frequency signal and
4.5MHz
TX DDS
circuit
10
CIRCUIT DESCRIPTION
5V #1
5V #1
4.5MHz
IC202
DDS IC
Q211
Fig. 4 Transmitter DDS circuit
IC102
OP-AMP
5V #2
IC101
PLL IC
9
4
1/R
PD
Fref.=4.5MHz
R=45
1/N
Fpd=100kHz
6
Fig. 5 Transmitter main PLL circuit
ence frequency signal based on 19.2MHz on signal.
The spurious output by IC202 is attenuated by CF201
and LPF, 4.5MHz reference frequency signal is amplified
by Q211, Q212, and Q213, and fed to the transmitter main
PLL.
The comparison frequency of the transmitter main PLL is
100kHz and the PLL frequency step is 100kHz.
However, minute frequency step such as 2.5kHz and
3.125kHz because the DDS output frequency is variable.
5V #1
CF201
ATT
Q212
transmitter PLL reference signal (4.5MHz), and compares
the phase with the 100kHz comparison frequency.
The phase difference signal produced by the comparing
phase is converted to a DC voltage by a lag-lead type loop
fi lter.
The DC signal is applied to varicaps D101, D102, D107,
and D108 to lock the VCO oscillator frequency with the de-
sired oscillator frequency.
At the same time, the DC signal passes through the
IC102 operational amplifier for monitoring the transmitter
main PLL lock voltage.
The output from the VCO passes through the buffer am-
plifi er Q104 and is supplied to the drive circuit.
9V'
CVT
9V'
9V'
450~
D108
464.995MHz
Q102
Q104
9V'
465~
D102
480MHz
Q103
5V #2
ATT
Q106
5V #1
4.5MHz
TX main
ATT
PLL circuit
Q213
450~
480MHz
Driver
circuit
ATT