NXR-800
Flat cable (36-pin) about 256mm (E37-0979-05)
ANT Jig for BPF adjustment (E30-3418-08)
Test Signaling
■ Analog
No.
Decode tone
1
None
2
None
3
QT 67.0Hz
4
QT 151.4Hz
5
QT 210.7Hz
6
QT 254.1Hz
7
DQT D023N
8
DQT D754I
9
None
10
None
11
DTMF decode (Code: 159D) DTMF encode (Code: 159D)
12
None
13
None
■ NXDN
No.
Decode tone
1
RAN1
2
RAN1
3
RAN1
• Signaling number 1 is used for link test with voice.
• Signaling number 2 is used for TX modulation signal qual-
ity test. i.e, TX adjacent channel power, FSK error, Occu-
pied bandwidth, Emission mask, etc.
• Signaling number 3 is used for TX deviation test. If the
modulation mode is very narrow, the modulation fre-
quency is 600Hz. If the modulation mode is narrow, the
modulation frequency is 1200Hz.
72
ADJUSTMENT
Encode tone
None
100Hz square wave
QT 67.0Hz
QT 151.4Hz
QT 210.7Hz
1QT 254.1Hz
DQT D023N
DQT D754I
CWID encode (ID: VVV)
Single tone
DTMF encode (Code: 9)
Courtesy tone
Encode tone
RAN1
PN9
Maximum deviation pattern
2.5MHz
2.5MHz
3dB max.
Fig. 1
7.5kHz
7.5kHz
3dB
max.
30kHz
30kHz
Fig. 2
3.75kHz
3.75kHz
3dB max.
12.5kHz
12.5kHz
Fig. 3
More
than
55dB
More
than
35dB