Terminal Function - Kenwood NXR-800 Service Manual

Uhf digital base-repeater
Hide thumbs Also See for NXR-800:
Table of Contents

Advertisement

NXR-800
Final Unit (X45-3820-10) (A/5)
Pin No.
Name
I/O
CN1 (To X56-312 A/3 CN802)
1
TX SIGNAL
I
CN2 (To X45-382 C/5 CN29)
1
SB
I
1
-
O 5V supply output for FAN
2
-
-
1
MONITOR
O Receive signal input (Coaxial)
CN20 (To X56-312 A/3 CN806)
1
GND
-
2
GND
-
3
NC
-
4
GND
-
5
PA_CURR
O Power module current monitor
6
GND
-
7
FAN_CURR
O FAN current monitor
8
GND
-
9
FWD_PWR
O TX Forward power detection
10
GND
-
11
RFL_PWR
O TX Refl ect power detection
12
GND
-
13
PWR_PRT
I
14
GND
-
15
PWR_CONT
I
16
GND
-
17
FAN_CONT
I
18
GND
-
19
FAN_CONT2
I
20
GND
-
21
TEMP_RST
I
22
GND
-
23
ANT_SW
I
24
GND
-
25
TEMP_PRT
O High temperature detect
26
DGND_
-
27
CONT_5.0V
I
28
DGND_
-
29
SCL
I
30
D_GND
-
31
SDA
I/O Data input/output for E2PROM
28

TERMINAL FUNCTION

Function
Tx driver input signal (Coaxial)
Power supply input
CN8
Ground
CN19
Ground
Ground
No connection
Ground
Ground
Ground
Ground
Ground
TX power protection
Ground
TX power control
Ground
FAN1 control
Ground
FAN2 control
Ground
Reset input for temperature detect IC
Ground
Antenna switch
Ground
Digital ground
Switched 5V supply
Digital ground
Clock input for E2PROM
Digital ground
Pin No.
Name
I/O
32
D_GND
-
Digital ground
33
GND
-
Ground
34
WP
I
Write protection input for E2PROM
35
GND
-
Ground
36
GND
-
Ground
CN21 (To X45-382 C/5 CN30)
1
E
-
Ground
Final Unit (X45-3820-10) (C/5)
Pin No.
Name
I/O
CN11 (To X53-413 CN4)
1
E
-
Ground
2
-
-
No connect
3
SB
O Power supply output
4
SB
O Power supply output
CN12 (To X56-312 CN801)
1
E
-
Ground
2
SB
O Power supply output
3
SB
O Power supply output
CN15 (To X55-310 CN44)
1
E
-
Ground
2
SB
O Power supply output
3
SB
O Power supply output
Final Unit (X45-3820-10) (D/5)
Pin No.
Name
I/O
CN701 (To X55-310 CN6/CN36)
1
-
I
9V supply input
2
-
-
Ground
3
-
O -3V supply output
4
-
-
Ground
Final Unit (X45-3820-10) (E/5)
Pin No.
Name
I/O
CN905 (To X56-312 B/3 CN923)
1
VOLUME_IN
O Volume control output for AF signal
2
33MPU
I
3.3V constant voltage
3
GND
-
Ground
4
33AUD
I
3.3V constant voltage
5
SB
I
Power supply input
6
SCM_EN
-
No connection
7
GND
-
Ground
Function
Function
Function
Function

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents