Introduction; Important Information - Vistacool V7501 Installation Manual & Owner's Manual

Table of Contents

Advertisement

Introduction

VistaCool is a patent-pending system designed to eliminate the
need for autoclave condenser/waste bottles and condensation
tanks by cooling the exhaust water and automatically sending
it directly down the drain� With the use of a simple adapter kit,
the VistaCool Model V7502 is designed to enable the Midmark
M9 and M11 autoclaves to use fresh deionized/distilled water for
each sterilizing cycle—converting these chambered autoclaves to
operate like quick-turnaround, cassette systems� This eliminates
the repeated use of autoclave water, keeping the chamber
cleaner, while also eliminating reservoir draining and maintenance�

IMPORTANT INFORMATION

For System Owners
We recommend that a professional technician or plumber familiar with dental/medical offices perform the
installation since interface with a cold water line and drain is involved� He/she should be familiar with local
plumbing codes and techniques for successful dental/medical equipment installations� Failure to install
correctly could result in water leaks, leading to possible water damage� It is the responsibility of the system
owner to validate the use of all equipment within its installed environment�
Please keep the Installation Guide & Owner's Manual handy for future reference and ensure that anyone
responsible for operation and maintenance of the system is familiar with all details contained in this manual�
Please return the Warranty Registration form or register online immediately upon installation�
IMPORTANT INFORMATION
For System Installers
Please read this entire manual before proceeding with installation and operation, and always follow local
plumbing codes�
VistaCool systems have only been verified for installation on the compatible autoclaves (listed above)�
Please check with the manufacturer of other brands of autoclaves or contact Vista Research Group before
connecting to other than SciCan or Midmark autoclaves� See page 13 for autoclave-specific instructions�
VistaCool Model V7502 has been verified for installation on Midmark M9 & M11 units with the use of
the S7560 adapter kit� Only M9, M9D, M11 and M11D (-02X, -03X) units with
connected to VistaCool� First generation models with
The VistaCool tank must be installed so that the top of the water tank is ABOVE the connection to the
drain adapter� Please see page 12 for important tank positioning details�
Check for leaks and run the autoclave(s) for at least two consecutive cycles after installation to
ensure the system is operating properly�
© 2000-2015 Vista Research Group, LLC. All rights reserved.
VistaCool can be used with:
Midmark M3
Midmark M9*
Midmark M11*
SciCan STATIM 2000
SciCan STATIM 5000
* Requires Model V7502 and S7560 adapter kit
green
red
displays (-0XX) are not compatible�
displays can be
3