5.2 The radio remote control
The remote control overrides the automatic function
The remote control is a 4 channel radio transmitter with the
following control functions:
1. Forwards. Press once for forward movement
To STOP press forward button again or backward button.
2. Backwards. Press once for backward movement.
To STOP press backwards or forwards button.
3. Left Turn
4. Right Turn
To set the cleaner in manual mode use the switch on the control box.
When this is done the sensors are de-activeted.
5.3 Running the vacuum in the pool
First make sure that nobody is in the pool.
If the Trolley with the control box is used leave the Trolley at a minimum of 2 meters (7 ft) from the edge
of the pool (Check any local regulations that may apply).
Roll out the floating cable (umbilical) and stretch it out as straight as possible.
Check the electrical outlet to make sure that the voltage that will be used corresponds to that of the pool
vacuum. Make sure that the outlet is equipped with a GFCI, ELCB or RCD (See above). Contact a local electri-
cian if you have any hesitations about this prior to connecting the power cable!
Fit the filter on the vacuum.
Connect the Power cable.
Turn the power on and drive the cleaner carefully into the pool. It is important to place the floating cable
into the pool since it is cooled by the pool water. To avoid over heating do not drive the vacuum cleaner
out of the pool for more than 5 minutes per hour.