Installation Of Field Installed Accessories - Lincoln Electric TIG MODULE IM528-B Operator's Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

If using a water cooled torch with a water cooler,
do not install the water valve. It will block the
water flow, possibly damaging the pump.
Magnum water coolers are an exception to this
rule. Refer to the manufacturer's instructions
provided with the cooler.
INSTALLATION OF FIELD INSTALLED
ACCESSORIES
Installation of the K963 Hand Amptrol, K870 Foot
Amptrol, and K814 Arc Start Switch is as follows:
Connect the 6-pin MS-type circular connector to
the Remote Receptacle on the TIG Module.
Secure with the threaded collar.
Installation of the K936-[ ] Input Cables and K937-[ ]
Extension Cables is as follows:
Connect the 9-socket MS-type circular connector
on the Input Cable to the Input Receptacle on the
TIG Module. Secure with the threaded collar. If
one or more K937-[ ] Extension Cables are used,
connect them between the TIG Module and the
K936-[ ] Input cable.
Installation instructions for the K938-1 Contactor Kit,
K844-1 Water Valve Kit and the K939-1 Docking Kit
are included with those kits.