Disassembly Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge
capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be
connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational.
12. Lift off Filter/Flowplate Assembly to access Chopper
Plate.
13. Remove 3 Torx™ screws to remove Chopper Plate.
14. Lift off Chopper
15. Remove Chopper Sleeve by using Impeller as a
wrench. Lock motor rotation using the access hole
provided in back of motor.
16. Lift off Seal Seat Assembly.
©2006 Maytag Services
!
WARNING
16026945
33