EMS 110 User Manual

Precision ultrasound balance

Advertisement

Quick Links

E M S P h ys i o L td .
Grove Technology Park
Downsview Road
Wantage
Oxfordshire OX12 9FE
England

User Manual

PRECISION ULTRASOUND
BALANCE
Model 110

Advertisement

Table of Contents
loading

Summary of Contents for EMS 110

  • Page 1: Title

    E M S P h ys i o L td . Grove Technology Park Downsview Road Wantage Oxfordshire OX12 9FE England User Manual PRECISION ULTRASOUND BALANCE Model 110...
  • Page 2: Declaration Of Conformity

    Declaration of Conformity NOTICE: This equipment has been tested and found to comply with the limits class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 3: General Information

    The information contained in this manual is subject to change without notice. No part of this manual may be photocopied, reproduced or translated into another language without the prior written consent of EMS Physio Ltd. Record of Amendments ISSUE COMMENTS...
  • Page 4: Table Of Contents

    Contents Page Title Declaration of Conformity General Information Record of Amendments Contents Warranty Introduction Technical Specifications Unpacking Assembled Balance Schematic (Fig 1) Assembly Controls and Markings Operating Instructions Maintenance Troubleshooting Parts List Precision Ultrasound Balance...
  • Page 5: Warranty

    Warranty This EMS Physio Ltd., (hereinafter called the company) product is warranted against defects in materials and workmanship for a period of two years from the date of shipment. The Company will at its option, repair or replace components which prove to be defective during the warranty period, provided that the repairs or replacements are carried out by the Company or its approved agents.
  • Page 6: Introduction

    Introduction The EMS Precision Ultrasound Balance has been developed in response to the increasing demand for equipment capable of testing and calibrating ultrasound therapy units. The balance is based on the principle of measuring the radiation force produced on a suitable target by an ultrasound transducer.
  • Page 7: Technical Specifications

    23 C. Readings will be approximately 2% low if the actual water temperature is 13 C, and 2% high for 33 C. The EMS Precision Ultrasound balance is supplied in a carrying case. Precision Ultrasound Balance...
  • Page 8: Unpacking

    Unpacking Upon receipt of the unit check for any damage which may have occurred in transit. If any signs of damage are found then retain all packing material and inform the carrier and the Company or its agent from whom the unit was purchased. Each unit is supplied with a low voltage adaptor and cable.
  • Page 9: Assembled Balance Schematic (Fig 1)

    Target Clamp Assembly Support stem Centralizing Plate (Various) Support Arm Assembly Container Level Indicator Electronic Balance Display Tare (Zero) Button (x2) Select Button Enter Button ON/OFF Button Figure 1 – Assembled Balance Precision Ultrasound Balance...
  • Page 10: Assembly

    Select a suitable workpiece clamp and fit to the stand support stem (the unit is supplied with quick release clamps for use with EMS heads and an adjustable clamp for use with other styles and sizes of heads).
  • Page 11: Controls And Markings

    Incorrect use will allow access to and possible corruption of conversion factors. The EMS serial number of the balance and month / year of manufacture is shown on the label attached at the side of the balance. Precision Ultrasound Balance...
  • Page 12: Operating Instructions

    The transducer may be held in place using a centralising plate and quick release attachment if it is an EMS device, otherwise use the universal clamp supplied.
  • Page 13: Maintenance

    If the reading is not within the above range it is recommended that the Ultrasound Balance is returned to EMS for calibration. Calibration of the Ultrasound Balance requires specialised test equipment and the balance must be returned to EMS Physio Ltd. Precision Ultrasound Balance...
  • Page 14: Troubleshooting

    Troubleshooting Symptom Probable Cause Remedy 1. No display Power adaptor not Connect power connected adaptor 2. Display HIGH Overweight indication Check target frame is not obstructed or damaged and container is full of water 3. The power Unstable ambient Set up the balance in reading changes conditions (excessive another area...
  • Page 15: Parts List

    Centralizing Plate, 1032 small head A67-3-08 Centralizing Plate, ML9120 A110-2-02 Mounting Block A110-3-01 Centralizing Plate, Primo/SoLo large head 1 A110-4-01 Front and Rear Labels label ‘EMS Physio’ A110-5-05 Support Arm Assembly B110-2-03 Stand Bracket B110-5-02 Target assembly C199 Clamp - general purpose...