B-2
No external shielding gas is required when used
with Lincoln .035" (0.9 mm) Innershield NR ® -211-
MP electrode.
Accommodates both 4" (100 mm) diameter and 8"
(200 mm) diameter spools of wire.

WELDING CAPABILITY

The SP-100T is rated at 88 amps, 18 volts, at 20%
duty cycle on a ten minute basis. CSA rated output at
62 amps at 20 volts at 20% duty cycle. It is capable of
higher output currents at lower duty cycles.

LIMITATIONS

Arc Gouging cannot be performed with the SP-100T.
The SP-100T is not recommended for pipe thawing or
TIG welding.

CONTROLS AND SETTINGS

Refer to Figure B.1a.
1. Control Power ON/OFF Switch
— When the power is on the
fan motor will run and air will be
exhausted out the louvers in the
front of the machine. The weld-
ing output and wire feeder
remain off until the gun trigger
is pressed.
2. Wire Speed Control —
Controls the wire feed speed
from 50 – 300 in /min (1.3 –
7.6 m/min). The control can
be preset on the dial to the
setting specified on the SP-
100T Application Chart
located on the inside of the
wire feed section door.
3. Voltage Control — A 4-posi-
tion tap selector switch gives
full range adjustment of
power source output voltage.
Do not switch while welding.
Refer to Figure B.1b.
4. Circuit Breaker – Protects machine from damage if
maximum output is exceeded. Button will extend
out when tripped (Manual reset).
OPERATION
5. Gun Trigger - Activates welding output, wire feed,
OFF
ON
WIRE SPEED
ARC VOLTS
SP-100T
and gas solenoid operation. Releasing the trigger
deactivates welding and simultaneously activates
the "burnback" function so that the welding wire
does not stick in the weld puddle.
FIGURE B.1a
1
SP-100T
FIGURE B.1b
+
-
5
B-2
2
3
DO NOT SWITCH
WHEN WELDING
4

Hide quick links: