Operation Procedure Of Diag Menu And Sub-Menu; Functions In Diag Mode; Initial Settings Used To Start Diag - Yamaha RX-V540 Service Manual

Av receiver/av amplifier
Hide thumbs Also See for RX-V540:
Table of Contents

Advertisement

RX-V540/RX-V540RDS/HTR-5650/HTR-5650RDS/DSP-AX540
RX-V440/RX-V440RDS/HTR-5640/HTR-5640RDS/DSP-AX440
• Operation procedure of DIAG menu and
SUB-MENU
There are 15 MENU items, each of which has some SUB-
MENU items.
DIAG menu selection
Main unit: Select the menu using
(Reverse) keys of PRESET/TUNING.
SUB-MENU selection
Main unit: Select the sub-menu using
(Reverse) keys of PROGRAM.

• Functions in DIAG mode

In addition to the DIAG menu items, functions as listed
below are available.
• Input selection, 6CH input
• Center/Rear/Rear Center/Sub-woofer level adjustment
• Muting
• Power on/off
• Master volume
* Functions related to the tuner and the set menu are not
available.
* It is possible to confirm Menu No.11 IF STATUS while
keeping the signal process (operation status) of each
DIAG menu by using the input mode key of the main
unit.

• Initial settings used to start DIAG

The following initial settings are used when starting DIAG.
When DIAG is canceled, these settings are restored to
those before starting DIAG.
• Master volume: -40dB
• Input: DVD (6CH INPUT OFF)
• Effect level: 0dB
• Audio mute: OFF
• Speaker setting: LARGE / BASS OUT = BOTH
• DIAG menu: DSP THROUGH (1. ANALOG BYPASS)
26
(Forward) and
(Forward) and
Keys of main unit
SUB-MENU selection
DIAG menu selection