Indoor Unit (Ras-13Ukp-Es4, Ras-10Ukp-Es4, Ras-07Ukp-Es4); Outdoor Unit (Ras-10Ua-Es4) - Toshiba RAS-13UKHP-ES4 Service Manual

Split wall type
Table of Contents

Advertisement

4-5. Indoor Unit (RAS-13UKP-ES4, RAS-10UKP-ES4, RAS-07UKP-ES4)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
Transformer
3
4
Microcontroller unit (IC30)
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Bridge rectifier (DB50)
8
Capacitor (C50)
9
Fuse (F01)
V aristor (R21, R22)
10
Louver motor
11
12
Relay (Comp., RY01)

4-6. Outdoor Unit (RAS-10UA-ES4)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Type
SKF-220-20-4A-1
TT-10
TMP87CM40AN
*SS11V-06270
KBP06M/51
PF1E222MNN1625
BET6.3A
15G561K320
MP24Z
DI1U
Type
Output (Rated) 750W, 2poles, 1 phase, 220 − 240V, 50Hz
PA108X1C-4FZDN Winding resistance (Ω)
(at 20°C)
Output (Rated) 20W, 6poles, 1 phase, 220 − 240V, 50Hz
HF-240-20B or
Winding resistance (Ω)
SKF-240-20B
(at 20°C)
DS451155NPQB
AC 450V, 1.5µF
DS441256CPNAL AC 440V, 25µF
− 17 −
FILE NO. SVM-05020
Specifications
AC Motor with 150°C thermo fuse
10kΩ at 25°C
10kΩ at 25°C
27mH, 600mA
1.5A, 600V
2200µF, 25V
T6.3A, 250VAC
560V
12VDC
Rating 25A/AC250V, 3~48VDC
Specifications
C-R
3.75
Red-Black
387.3 or 235.2
C-S
4.75
White-Black
466.2 or 260.1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents