3. Ceiling Fan Assembly
3.6
The fan comes with blue, black and white leads that are
42" long.
Measure up approximately 6 to 9-inches above top of
hanger ball/4.5" downrod assembly (Figure 5).
Cut off excess leads and strip back insulation 1/2-inch
from end of leads.
3.7
Carefully turn the partially assembled ceiling fan over
and place it on the styrofoam for final preparation
(Figure 6).
3.8
Remove the shipping spacers and the spacer
attachment screws from the motor before installation of
blade assemblies (Figure 7).
Discard the spacers and spacer screws.
(Continued)
Figure 5
PARTIALLY ASSEMBLED
CEILING FAN
Figure 6
SPACER ATTACHMENT SCREW
SHIPPING SPACER
Figure 7
Please contact 1-800-654-3545 for further assistance
7
6 to 9
INCHES
HANGER BALL/
DOWNROD
ASSEMBLY
STYROFOAM