Set-Up Feature Menu - Lincoln Electric POWER WAVE C300 CE Operator's Manual

Lincoln electric welder user manual
Hide thumbs Also See for POWER WAVE C300 CE:
Table of Contents

Advertisement

B-27
The Setup Menu gives access to the Setup Configuration. Stored in the setup configuration are user parameters
that generally only need to be set at installation. The parameters are grouped as shown in the following table.
PARAMETER
P.1 through P.99
P.101 through P.199
P.501 through P.599
L e f t
S E T K n o b
b u t t o n
R i g h t
M o d e
L E D
b u t t o n
S e t - U p
M a i n D i s p l a y P a n e l
M o d e S e l e c t
OPERATION
SETUP MENU FEATURES
Secured Parameters (only accessible through a p.c. or palm application)
SET-UP FEATURES MENU
(See Figure B.16)
1. To access the set-up menu, press the Right and
Left buttons of the Main Display panel simultane-
ously. Note that the set-up menu cannot be
accessed if the system is welding, or if there is a
fault (The status LED is not solid green).
Change the value of the blinking parameter by rotat-
ing the SET knob.
2. After changing a parameter it is necessary to press
the Right hand button to save the new setting.
Pressing the Left button will cancel the change.
3. To exit the set-up menu at any time, press the
Right and Left buttons of the Main Display panel
simultaneously.
Alternately, 1 minute of inactivity
will also exit the set-up menu.
FIGURE B.16 - SETUP MENU
Mode Select
Main Display Panel
Left
button
SET Knob
POWER WAVE® C300 CE
DEFINITION
Unsecured Parameters (always adjustable)
Diagnostic Parameters (always read only)
Right
button
LED
Set-Up
Mode
B-27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents