FUTABA 14SG S.Bus2 Instruction Manual page 110

14 channel computer system
Table of Contents

Advertisement

Dual rate setting procedure
1. Function selection
Move the cursor to the function selection
item and touch the RTN button to switch to
the data input mode.
Select the function you want to adjust by
scrolling the touch sensor.
Touch the RTN button to the cursor mode.
2. Switch selection
Move the cursor to the circuit # item and
access the switch setup screen by touching
the RTN button. Select the switch activation
method and the activation position (if
applicable).
*For a detailed description of the setting method, see [Switch
Setting Method] at the back of this manual.
3. Left/right (up/down) rate adjustment
*Perform the settings below after changing to the circuit # or
condition you want to adjust.
Move the cursor to the rate item you want to
adjust and touch the RTN button to switch to
the data input mode.
Adjust the rate by scrolling the touch sensor.
Initial value: 100%
Adjustment range: 0%~140%
*When the RTN button is touched for one second, the servo
operation position is reset to the initial value.)
Touch the RTN button to end the adjustment
and return to the cursor mode.
Repeat this procedure for additional rate
and other functions as desired.
4. Operation curve (EXP curve) adjustment
*Perform the settings below after changing to the circuit # or
condition you want to adjust.
Move the cursor to the EXP item you want to
adjust and touch the RTN button to switch to
the data input mode.
Adjust the rate by scrolling the touch sensor.
Initial value: 0%
Adjustment range: -100%~+100%
*When the RTN button is touched for one second, the servo
operation position is reset to the initial value.)
*Using the EXP curve is effective to smoothe or soften the
control inputs around center to avoid over-controlling the
model. This is often used for the ailerons, elevator and
rudder and may be used with the throttle in the case of an
airplane selection to smoothe the engine controls as well.
Touch the RTN button to end adjustment and
return to the cursor mode.
Repeat this procedure for all other rates and
functions as desired.
110
<Model Menu (Common Functions)>
5. Neutral position adjustment
*Perform the settings below after changing to the circuit # or
condition you want to adjust.
Move the cursor to the [NT] item and touch
the RTN button to switch to the data input
mode.
Adjust the rate by scrolling the touch sensor.
Initial value: 0%
Adjustment range: -100%~+100%
*When the RTN button is touched for one second, the neutral
position is reset to the initial value.)
Touch the RTN button to the cursor mode.

Advertisement

Table of Contents
loading

Table of Contents