7-2. Operation Data

<Cooling>
Temperature
condition (°C)
Model name
RAS-
Indoor
Outdoor
B10SKVP-E
10SKVP-ND
B13SKVP-E
27/19
35/–
13SKVP-ND
B16SKVP-E
16SKVP-ND
<Heating>
Temperature
condition (°C)
Model name
RAS-
Indoor
Outdoor
B10SKVP-E
10SKVP-ND
B13SKVP-E
20/–
7/6
13SKVP-ND
B16SKVP-E
16SKVP-ND
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
1.0 to 1.2
13 to 15
0.9 to 1.1
10 to 13
0.8 to 1.0
8 to 11
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
2.1 to 2.3
37 to 39
2.4 to 2.6
41 to 44
2.8 to 3.0
48 to 50
www.ilmalämpöpumput.com
– 24 –
Indoor
fan mode
T2 (°C)
36 to 39
High
37 to 39
High
37 to 40
High
Indoor
fan mode
T2 (°C)
3 to 5
High
2 to 4
High
2 to 4
High
Compressor
Outdoor
revolution
fan mode
(rps)
High
35
High
56
High
82
Compressor
Outdoor
revolution
fan mode
(rps)
High
46
High
62
High
85