824755-YTG-C-0912
ELECTRIC HEAT PERFORMANCE DATA: 208/230-1-60 & 208/230-3-60
Heater
1,2
Models
6HK(0,1)6500206
6HK(0,1)6500506
6HK(0,1)6500806
6HK(0,1)6501006
1PH
6HK(1,2)6501306
6HK(1,2)6501506
6HK(1,2)6501806
6HK(1,2)6502006
6HK(1,2)6502506
6HK06501025
6HK06501525
3PH
6HK06501825
6HK16502025
6HK16502525
1. (0,1) - 0 = no circuit breaker OR 1 = with circuit breaker.
2. (1,2) - 1 = with circuit breaker, no breaker jumper bar OR 2 = with circuit breaker & breaker jumper bar.
3. For different power distributions, see conversion table on Page 5.
6
Nominal kW
kW
@240V
208V
230V
2.4
1.8
2.2
4.8
3.6
4.4
7.7
5.8
7.1
9.6
7.2
8.8
12.5
9.4
11.5
14.4
10.8
13.2
17.3
13.0
15.9
19.2
14.4
17.6
24.0
18.0
22.0
9.6
7.2
8.8
14.4
10.8
13.2
17.3
13.0
15.9
19.2
14.4
17.6
24.0
18.0
22.0
3
Total Heat
MBH
208V
230V
6.2
7.5
12.3
15.0
19.7
24.1
24.6
30.1
32.0
39.2
36.9
45.1
44.3
54.2
49.2
60.2
61.5
75.2
24.6
30.1
36.9
45.1
44.3
54.2
49.2
60.2
61.5
75.2
kW Staging
W1 Only
W1 + W2
208V
230V
208V
1.8
2.2
1.8
3.6
4.4
3.6
5.8
7.1
5.8
7.2
8.8
7.2
3.1
3.8
9.4
3.6
4.4
10.8
6.5
7.9
13.0
7.2
8.8
14.4
7.2
8.8
18.0
7.2
8.8
7.2
10.8
13.2
10.8
13.0
15.9
13.0
7.2
8.8
14.4
9.0
11.0
18.0
Johnson Controls Unitary Products
230V
2.2
4.4
7.1
8.8
11.5
13.2
15.9
17.6
22.0
8.8
13.2
15.9
17.6
22.0