Sunpak S25 Installation, Operation & Maintenance Manual

Sunpak S25 Installation, Operation & Maintenance Manual

Sunpak gas-fired, unvented high-intensity infrared heaters for use indoor/outdoor not for use in residential dwellings

Advertisement

Quick Links

FOR YOUR SAFETY:
If you smell gas:
1. Open windows.
2. DO NOT try to light any appliance
3. DO NOT use electrical switches
4. DO NOT use any telephone in your
building
5. Leave the building
6. Immediately call your local gas
supplier after leaving the building.
Follow the gas supplier's
instructions.
7. If you cannot reach your gas
supplier, call the Fire Department
WARNING
Fire Hazard
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any appliance.
Failure to follow these instructions can result
in death, injury or property damage.
WARNING
Fire and Explosion
Improper installation, adjustment, alteration,
service or maintenance can result in death,
injury or property damage. Read the
installation, operation and service manual
thoroughly before installing or servicing this
equipment.
Installation and replacement of gas piping,
gas utilization equipment, or accessories,
and repair and servicing of equipment shall
be performed by a qualified agency familiar
will all precautions required regarding this
type of equipment and that has complied
with all requirements of the authority having
jurisdiction.
© Copyright 2014 Infrared Dynamics, Inc.
Printed in the U.S.A.
Infrared Dynamics
SUNPAK
Not for use in residential dwellings
NOTE: See page 2 for Definition of Outdoors
& Maintenance Manual
Please take the time to read and understand these
instructions prior to any installation. Installer must be
given a copy of this manual to the owner.
Keep this manual in a safe place in order to provide
your serviceman with the necessary information.
Infrared Dynamics, Inc.
3830 Prospect Avenue
Yorba Linda, CA 92886
Telephone: (714) 572-4050
Fax: (714) 572-6093
Toll Free: (888) 317-5255
www.sunpak.us
Gas-Fired, Unvented
High-Intensity
Infrared Heaters
For use Indoor/Outdoor
Installation, Operation
Model S25
Model S34
Installer
Owner
P/N 65134-7/14
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S25 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sunpak S25

  • Page 1 Failure to follow these instructions can result in death, injury or property damage. WARNING Model S25 Fire and Explosion Model S34 Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage.
  • Page 2 When plastic curtains or drops are used to  Never attempt to manually light the burner with a enclose a patio you must take steps to insure that Sunpak match or other source of flame. heaters have the required permanent access to outside air.
  • Page 3 Sunpak heaters may be laid out in a number of configurations depending on the structural constraints of the patio and heating requirements. One approach is to face heaters straight down over the table and seating areas.
  • Page 4 Sunpak® Infrared Heaters CEILING MINIMUM CLEARANCE FROM COMBUSTIBLE MUST BE MAINTAINED (see chart opposite page SUNPAK will raise the comfort level 5-10º Fahrenheit ANGLE MOUNTING: Most models of the SUNPAK outdoors. The above coverage table was based on heater may be angle-mounted to a maximum of 30º...
  • Page 5 Sunpak® Infrared Heaters © Copyright 2014 Infrared Dynamics, Inc. P/N 65134-6/14...
  • Page 6: Installation Instructions

    48” 30º MAX 34,000 24” 8” 18” 48” 30º MAX Above clearance apply to models on either natural or LP gas. *Model S25 for LP gas for use in horizontal position only © Copyright 2014 Infrared Dynamics, Inc. P/N 65134-6/14...
  • Page 7 Sunpak® Infrared Heaters © Copyright 2014 Infrared Dynamics, Inc. P/N 65134-6/14...
  • Page 8 Sunpak® Infrared Heaters Fire Sprinklers CAUTION Fire Sprinklers must be located at an appropriate distance from each heater to avoid accidental Sharp Edges activation of the sprinkler. Ethylene glycol or Every effort has been made to remove sharp propylene glycol must never be used in fire sprinkler edges from this heater;...
  • Page 9: Gas Piping

    Sunpak® Infrared Heaters Ventilation Initial Start-Up Procedure It is required that areas above the heater be 1. Before turning on the manual gas valve to the heater properly vented to allow for necessary verify that the control system is working properly.
  • Page 10: Servicing Instructions

    Sunpak® Infrared Heaters Servicing Instructions Turn off gas and electrical before attempting any service to this appliance. Heater may be serviced by opening the door to control compartment. Rotate round disk on control door 90 degrees to open. Top of heater may be removed for servicing by removing six (6) screws holding top in place.
  • Page 11 Sunpak® Infrared Heaters...
  • Page 12 Sunpak® Infrared Heaters...
  • Page 13 Sunpak® Infrared Heaters...
  • Page 14 Sunpak® Infrared Heaters...
  • Page 15: Troubleshooting Guide

    Erratic winds  Deterioration of Front Grill Sunpak heater must be installed in such a manner as to allow the products of combustion or hot gases to vent out the top of the heater. When operating normally, only radiant heat passes through the front grill.
  • Page 16: Limited Warranty

    Sunpak® Infrared Heaters LIMITED WARRANTY THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY in accordance with the warranty terms and conditions specified below. One Year Homeowner Limited Warranty/90 Day Commercial Warranty Infrared Dynamics (warrantor) will furnish the original owner replacement parts for any component part which fails before one year of residential use , or 90 days commercial use, following installation.