Outdoor Unit
4-Way Valve Control
• When the unit is switched to "OFF"
during Heating operation, 4-way valve
stays at Heating Position for 5 minutes.
Overload Protector
• Inner protector (Compressor, Fan Motor).
60 Secs. Forced Operation Control
• Once the compressor is activated, it
does not stop for 60 secs. (Stops imme-
diately with remote control stop signal.)
Outdoor Fan Operation Control
• 4-pole induction motor (2-speed)
• For Cooling or Soft Dry Operation
Hi-speed ... when outdoor temperature
Lo-speed ... when outdoor temperature
• For Heating Operation
Hi-speed ... when outdoor temperature
Lo-speed ... when outdoor temperature
• For Over-heating Protection, the Fan is
switched ON or OFF depending on the
piping temperature and the outdoor
temperature.
Deice Control
• To prevent frosting at outdoor heat
exchanger during Heating Operation.
reaches to 31°C
reaches to 29°C
reaches to 13.5°C.
reaches to 15.5°C.
5
CS-A28BKP5/CU-A28BKP5